Robust organ mapped dose: using multiple image registrations to identify deformation uncertainty in radiation dose mapping

<i>Objective</i>. To assist with reirradiation (reRT) treatment planning, we propose a robust organ-mapped dose (ROAD) method for cumulative dose estimation within critical organs-at-risks (OARs), incorporating deformable image registration (DIR) uncertainty via a dose resampling kernel derived from organ-specific independent DIRs.<i>Approach</i>. The discordance among three distinct DIRs, each of unknown accuracy, was used to estimate spatial uncertainty. For each voxel within an OAR, the discordance generated a per-voxel dose-resampling kernel. Two additional kernel expansions incorporated uncertainties not captured by inter-DIR discordance: the first ensured all returned dose originated within the OAR, while the second ensured all OAR dose voxels were sampled. The maximum dose within the kernel-OAR intersection was assigned to each voxel to yield a robust dose map. The approach was demonstrated for five pelvic, five head-and-neck, and five thoracic reRT cases using DIR-mapped background doses. Kernel generation was analysed by tracking kernel magnitude and its correlation with mean distance to agreement (MDA) and Hausdorff distance. Resulting dose distributions were compared with baseline mapped doses and a fixed-kernel robustness method.<i>Main results</i>. Analysis confirmed generally well-chosen DIRs but revealed residual errors beyond DIR discordance, detected by the additional kernel expansions. ROAD produced dose distributions comparable to fixed-kernel methods under low deformation uncertainty but demonstrated greater robustness in regions with large anatomical variation, particularly in the pelvis. ROAD reduced instances where mapped near-maximum doses underestimated original values, without increasing overall dose, by capturing uncertainty from organ filling and positional changes missed by fixed-kernel accumulation.<i>Significance</i>. Accurate cumulative dose estimation is critical for safe and effective reRT planning. The proposed ROAD framework explicitly incorporates voxel-level DIR uncertainty, providing a more reliable OAR dose estimate in regions with substantial anatomical change. This enhances confidence in reRT dose assessment and offers a practical, robust tool for clinical evaluation of cumulative organ doses.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2026-02-26
DOI
https://doi.org/10.1088/1361-6560/ae4b01
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Robust organ mapped dose: using multiple image registrations to identify deformation uncertainty in radiation dose mapping

Michael Nix, Louise Murray, Stina Svensson, John Lilley et al.
Physics in Medicine and Biology
Advanced Radiotherapy Techniques
article

Robust organ mapped dose: using multiple image registrations to identify deformation uncertainty in radiation dose mapping

Michael Nix, Louise Murray, Stina Svensson, John Lilley, Christopher Pagett, Christopher Thompson, Ane L Appelt, Robin Prestwich
article en

Abstract

<i>Objective</i>. To assist with reirradiation (reRT) treatment planning, we propose a robust organ-mapped dose (ROAD) method for cumulative dose estimation within critical organs-at-risks (OARs), incorporating deformable image registration (DIR) uncertainty via a dose resampling kernel derived from organ-specific independent DIRs.<i>Approach</i>. The discordance among three distinct DIRs, each of unknown accuracy, was used to estimate spatial uncertainty. For each voxel within an OAR, the discordance generated a per-voxel dose-resampling kernel. Two additional kernel expansions incorporated uncertainties not captured by inter-DIR discordance: the first ensured all returned dose originated within the OAR, while the second ensured all OAR dose voxels were sampled. The maximum dose within the kernel-OAR intersection was assigned to each voxel to yield a robust dose map. The approach was demonstrated for five pelvic, five head-and-neck, and five thoracic reRT cases using DIR-mapped background doses. Kernel generation was analysed by tracking kernel magnitude and its correlation with mean distance to agreement (MDA) and Hausdorff distance. Resulting dose distributions were compared with baseline mapped doses and a fixed-kernel robustness method.<i>Main results</i>. Analysis confirmed generally well-chosen DIRs but revealed residual errors beyond DIR discordance, detected by the additional kernel expansions. ROAD produced dose distributions comparable to fixed-kernel methods under low deformation uncertainty but demonstrated greater robustness in regions with large anatomical variation, particularly in the pelvis. ROAD reduced instances where mapped near-maximum doses underestimated original values, without increasing overall dose, by capturing uncertainty from organ filling and positional changes missed by fixed-kernel accumulation.<i>Significance</i>. Accurate cumulative dose estimation is critical for safe and effective reRT planning. The proposed ROAD framework explicitly incorporates voxel-level DIR uncertainty, providing a more reliable OAR dose estimate in regions with substantial anatomical change. This enhances confidence in reRT dose assessment and offers a practical, robust tool for clinical evaluation of cumulative organ doses.

Physics in Medicine and BiologyVol. 71(6)
University of Leeds (GB), Leeds Teaching Hospitals NHS Trust (GB), St James's University Hospital (GB), RaySearch Laboratories (Sweden) (SE)
Good health and well-being
Openalex Percentile: Top 37%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies