Simultaneous and Interference-Free Electrochemical Monitoring of Cd <sup> 2 <b>+</b> </sup> , Cu <sup> 2 <b>+</b> </sup> , and Hg <sup> 2 <b>+</b> </sup> using a CoFe <sub>2</sub> O <sub>4</sub> @Fe-Pda MOF Composite

There is a high risk of heavy metal contamination to both the environment and the population; hence, special care and selective, trustworthy detection technology is required. This paper describes the preparation and use of a CoFe<sub>2</sub>O<sub>4</sub>@Fe-Pda metal-organic framework (MOF)-based electrochemical sensor to concurrently detect Cd<sup>2+</sup>, Cu<sup>2+</sup>, and Hg<sup>2+</sup> ions. The sensor exhibits a strong electrochemical response, characterized by well-resolved peak potentials for each target ion and a linear current response as the target ion concentration varies. Measurement of differential pulse voltammetry (DPV) provides a limit of detection (LOD) of 9.6 ppb Cd<sup>2+</sup> (10-55 ppb), 13.5 ppb Cu<sup>2+</sup> (5-55 ppb) and 12.0 ppb Hg<sup>2+</sup> (3-55 ppb) in individual analysis and 15 ppb, 8.45 ppb, and 11 ppb for simultaneous detection of Cd<sup>2+</sup>, Cu<sup>2+</sup>, and Hg<sup>2+</sup> ions, respectively. It is interesting to note that the presence of one metal ion does not affect the detection of the others, even at lower concentrations, which supports the sensor's high selectivity and minimal cross-reactivity. The increased sensing power can be ascribed to the synergistic effects between the magnetic CoFe<sub>2</sub>O<sub>4</sub> nanoparticles and the Fe-Pda MOF, which together enable rapid electron transfer, a high surface area, and the potential for specific molecular interactions. These results demonstrate the promise of the CoFe<sub>2</sub>O<sub>4</sub>@Fe-Pda MOF as a robust electrochemical sensing platform for tracking toxic heavy metals in real time under complex aqueous conditions.

Authors

Institutions

Publication Details

Journal
Langmuir
Published
2026-02-26
DOI
https://doi.org/10.1021/acs.langmuir.5c06499
Primary Topic
Electrochemical Analysis and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simultaneous and Interference-Free Electrochemical Monitoring of Cd 2 + , Cu 2 + , and Hg 2 + using a CoFe 2 O 4 @Fe-Pda MOF Composite

Javeed Ahmad Sheikh, Kowsar Majid, Sheema Jan
Langmuir
Electrochemical Analysis and Applications
article

Simultaneous and Interference-Free Electrochemical Monitoring of Cd 2 + , Cu 2 + , and Hg 2 + using a CoFe 2 O 4 @Fe-Pda MOF Composite

Javeed Ahmad Sheikh, Kowsar Majid, Sheema Jan
article en

Abstract

There is a high risk of heavy metal contamination to both the environment and the population; hence, special care and selective, trustworthy detection technology is required. This paper describes the preparation and use of a CoFe<sub>2</sub>O<sub>4</sub>@Fe-Pda metal-organic framework (MOF)-based electrochemical sensor to concurrently detect Cd<sup>2+</sup>, Cu<sup>2+</sup>, and Hg<sup>2+</sup> ions. The sensor exhibits a strong electrochemical response, characterized by well-resolved peak potentials for each target ion and a linear current response as the target ion concentration varies. Measurement of differential pulse voltammetry (DPV) provides a limit of detection (LOD) of 9.6 ppb Cd<sup>2+</sup> (10-55 ppb), 13.5 ppb Cu<sup>2+</sup> (5-55 ppb) and 12.0 ppb Hg<sup>2+</sup> (3-55 ppb) in individual analysis and 15 ppb, 8.45 ppb, and 11 ppb for simultaneous detection of Cd<sup>2+</sup>, Cu<sup>2+</sup>, and Hg<sup>2+</sup> ions, respectively. It is interesting to note that the presence of one metal ion does not affect the detection of the others, even at lower concentrations, which supports the sensor's high selectivity and minimal cross-reactivity. The increased sensing power can be ascribed to the synergistic effects between the magnetic CoFe<sub>2</sub>O<sub>4</sub> nanoparticles and the Fe-Pda MOF, which together enable rapid electron transfer, a high surface area, and the potential for specific molecular interactions. These results demonstrate the promise of the CoFe<sub>2</sub>O<sub>4</sub>@Fe-Pda MOF as a robust electrochemical sensing platform for tracking toxic heavy metals in real time under complex aqueous conditions.

LangmuirVol. 42(9)
Sopot University of Applied Science (PL)
Openalex Percentile: Top 41%
Electrochemical Analysis and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.