Dual-shot polarization digital holographic microscopy with phase bias equalization for full-field Jones matrix imaging

Polarization digital holographic microscopy (PDHM) enables noninvasive, quantitative mapping of birefringence via full-field Jones matrix analysis. Conventional implementations rely on multiple sequential acquisitions and are vulnerable to phase drift, whereas single-shot variants are optically complex and alignment sensitive. We introduce a simple dual-shot PDHM that reconstructs the full-field Jones matrix from two holograms acquired with orthogonal incident polarizations. A motorized half-wave plate sets the input states, and a polarization-sensitive CMOS camera records off-axis holograms that embed four analyzer channels per exposure. To suppress inter-shot phase drift, we propose a phase bias equalization that leverages isotropic reference regions to align complex phases across Jones elements. Experiments on biaxially oriented polypropylene (BOPP) films yield retardance and fast axis maps in agreement. Imaging of mouse brain sections and human cornea further demonstrates robust visualization of anisotropic microstructures. The method balances speed, hardware simplicity, and quantitative performance, offering an accessible route to polarization-sensitive biomedical imaging and full-field Jones matrix microscopy.

Publication Details

Journal
Biomedical Optics Express
Published
2026-02-26
DOI
https://doi.org/10.1364/boe.585564
Primary Topic
Digital Holography and Microscopy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dual-shot polarization digital holographic microscopy with phase bias equalization for full-field Jones matrix imaging

Biomedical Optics Express
Digital Holography and Microscopy
article

Dual-shot polarization digital holographic microscopy with phase bias equalization for full-field Jones matrix imaging

article en

Abstract

Polarization digital holographic microscopy (PDHM) enables noninvasive, quantitative mapping of birefringence via full-field Jones matrix analysis. Conventional implementations rely on multiple sequential acquisitions and are vulnerable to phase drift, whereas single-shot variants are optically complex and alignment sensitive. We introduce a simple dual-shot PDHM that reconstructs the full-field Jones matrix from two holograms acquired with orthogonal incident polarizations. A motorized half-wave plate sets the input states, and a polarization-sensitive CMOS camera records off-axis holograms that embed four analyzer channels per exposure. To suppress inter-shot phase drift, we propose a phase bias equalization that leverages isotropic reference regions to align complex phases across Jones elements. Experiments on biaxially oriented polypropylene (BOPP) films yield retardance and fast axis maps in agreement. Imaging of mouse brain sections and human cornea further demonstrates robust visualization of anisotropic microstructures. The method balances speed, hardware simplicity, and quantitative performance, offering an accessible route to polarization-sensitive biomedical imaging and full-field Jones matrix microscopy.

Biomedical Optics ExpressVol. 17(4)
Openalex Percentile: Top 41%
Digital Holography and Microscopy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.