Research on Thermal Performance and Structural Optimization of Finned Shell-and-Tube Storage Units for Air-Source Heat Pump Systems

Thermal storage tanks offer significant potential for addressing the performance degradation and supply–demand mismatch of air-source heat pump (ASHP) systems in cold regions. This study employs a combined numerical and experimental approach to systematically investigate the impacts of fin structure, composite phase change material (CPCM) composition, and inlet temperature on the performance of shell-and-tube storage units. Results indicate that natural convection is the dominant heat transfer mechanism, and the incorporation of expanded graphite (EG) substantially enhances the thermal conductivity of the PCM. A critical finding is the identification of an optimal finning coefficient range (4.16 to 5.68) that maximizes enhancement performance. A validated numerical model (error < 5%) and a predictive formula for melting time were developed. Experimental data show that the optimized finned structure reduces PCM melting time by 47% to 59%. This research provides theoretical and practical tools for designing high-efficiency thermal storage, supporting the development of flexible and integrated building energy systems.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2026-02-25
DOI
https://doi.org/10.3390/buildings16050909
Primary Topic
Phase Change Materials Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Thermal Performance and Structural Optimization of Finned Shell-and-Tube Storage Units for Air-Source Heat Pump Systems

Meng Wang, Yuyi Wang, Wenhe Zhou, Tianyang Zhang
Buildings
Phase Change Materials Research
article

Research on Thermal Performance and Structural Optimization of Finned Shell-and-Tube Storage Units for Air-Source Heat Pump Systems

Meng Wang, Yuyi Wang, Wenhe Zhou, Tianyang Zhang
article en

Abstract

Thermal storage tanks offer significant potential for addressing the performance degradation and supply–demand mismatch of air-source heat pump (ASHP) systems in cold regions. This study employs a combined numerical and experimental approach to systematically investigate the impacts of fin structure, composite phase change material (CPCM) composition, and inlet temperature on the performance of shell-and-tube storage units. Results indicate that natural convection is the dominant heat transfer mechanism, and the incorporation of expanded graphite (EG) substantially enhances the thermal conductivity of the PCM. A critical finding is the identification of an optimal finning coefficient range (4.16 to 5.68) that maximizes enhancement performance. A validated numerical model (error < 5%) and a predictive formula for melting time were developed. Experimental data show that the optimized finned structure reduces PCM melting time by 47% to 59%. This research provides theoretical and practical tools for designing high-efficiency thermal storage, supporting the development of flexible and integrated building energy systems.

BuildingsVol. 16(5)
Jilin Normal University (CN), China Railway Corporation (CN), Lanzhou Jiaotong University (CN)
Affordable and clean energy
Openalex Percentile: Top 43%
Phase Change Materials Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.