Quantifying Stress Shielding in Dental Implants: A Comparative Finite Element Study of Titanium, CFR-PEEK, and Ceramic Materials

<b>Background</b>: Stress shielding, which occurs when there is a mismatch between the stiffness of the implant and the bone, can alter load transfer and drive peri-implant bone remodeling, particularly in low-density bone. <b>Methods</b>: We compared the biomechanical responses of one-piece implants made of Ti-6Al-4V, Y-TZP, and CFR-PEEK. We modelled the bone as linearly isotropic in the transverse direction and the implants as linearly isotropic with a fully bonded interface. A static load of 200 N was applied at an inclination of 30° buccal-to-lingual, with the transverse bone bottom faces fully constrained. <b>Results</b>: The peak cortical von Mises stress was highest for Y-TZP (87 MPa), followed by Ti-6Al-4V (57 MPa) and CFR-PEEK (approximately 37 MPa). Peak cortical von Mises strain showed the same relative order of magnitude: 3450 µε, 3103 µε, and 1523 µε, respectively. The stress-shielding factor (SSF) revealed that shielding was present in the mid-apical regions. Y-TZP exhibited the greatest shielding (SSF: 0.844-0.877), followed by Ti-6Al-4V (SSF: 0.380-0.568) and CFR-PEEK (SSF: 0.375-0.437). No crestal shielding was observed (SSF < 0). <b>Conclusions</b>: Overall, implants with higher stiffness increased crestal stress concentration and deepened peri-implant shielding. Meanwhile, CFR-PEEK improved load sharing and produced a more homogeneous mechanical stimulus in low-density bone.

Authors

Institutions

Publication Details

Journal
Materials
Published
2026-02-26
DOI
https://doi.org/10.3390/ma19050869
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantifying Stress Shielding in Dental Implants: A Comparative Finite Element Study of Titanium, CFR-PEEK, and Ceramic Materials

Adriano Piattelli, Luciano Lamberti, Bartolomeo Trentadue, Mario Ceddia et al.
Materials
Dental Implant Techniques and Outcomes
article

Quantifying Stress Shielding in Dental Implants: A Comparative Finite Element Study of Titanium, CFR-PEEK, and Ceramic Materials

Adriano Piattelli, Luciano Lamberti, Bartolomeo Trentadue, Mario Ceddia, Natalia Di Pietro, Alessandro Cipollina, Tea Romasco
article en

Abstract

<b>Background</b>: Stress shielding, which occurs when there is a mismatch between the stiffness of the implant and the bone, can alter load transfer and drive peri-implant bone remodeling, particularly in low-density bone. <b>Methods</b>: We compared the biomechanical responses of one-piece implants made of Ti-6Al-4V, Y-TZP, and CFR-PEEK. We modelled the bone as linearly isotropic in the transverse direction and the implants as linearly isotropic with a fully bonded interface. A static load of 200 N was applied at an inclination of 30° buccal-to-lingual, with the transverse bone bottom faces fully constrained. <b>Results</b>: The peak cortical von Mises stress was highest for Y-TZP (87 MPa), followed by Ti-6Al-4V (57 MPa) and CFR-PEEK (approximately 37 MPa). Peak cortical von Mises strain showed the same relative order of magnitude: 3450 µε, 3103 µε, and 1523 µε, respectively. The stress-shielding factor (SSF) revealed that shielding was present in the mid-apical regions. Y-TZP exhibited the greatest shielding (SSF: 0.844-0.877), followed by Ti-6Al-4V (SSF: 0.380-0.568) and CFR-PEEK (SSF: 0.375-0.437). No crestal shielding was observed (SSF < 0). <b>Conclusions</b>: Overall, implants with higher stiffness increased crestal stress concentration and deepened peri-implant shielding. Meanwhile, CFR-PEEK improved load sharing and produced a more homogeneous mechanical stimulus in low-density bone.

MaterialsVol. 19(5)
University of Chieti-Pescara (IT), Saint Camillus International University of Health and Medical Sciences (IT), Polytechnic University of Bari (IT), Universidad Católica de Murcia (ES)
Openalex Percentile: Top 43%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.