Detecting multiple fiducial markers from a camera seismocardiogram

Seismocardiogram (SCG) records the cardiac contractions and valve functions, holding a promising avenue for the early detection of adverse cardiovascular events. To monitor such events, it is crucial to accurately identify the fiducial markers in the SCG signal in order to support the estimation of hemodynamic parameters. In this paper, we propose a novel framework that consists of a defocused camera-based speckle imaging system to measure the SCG signal and a deep learning based model (DiAT) to detect multiple fiducial markers. Specifically, DiAT employs dilated convolution and a multi-head attention mechanism to capture the temporal context of SCG signals for detecting seven fiducial markers (MC, IM, AO, IC, RE, AC, MO). The percentage of predicted values falling in the range of true values ± 1 ms, and the Mean Absolute Error (MAE) between the predicted value and the true value are used as evaluation metrics. Experiments involving 17 adult subjects with ice water stimulation protocol show that DiAT obtains 87.78% accuracy and 8.4106 ms MAE. It demonstrates that our proposed method has reliable performance in detecting seven fiducial markers of camera-SCG signals.

Authors

Institutions

Publication Details

Journal
Biomedical Optics Express
Published
2026-02-26
DOI
https://doi.org/10.1364/boe.588787
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detecting multiple fiducial markers from a camera seismocardiogram

Caifeng Shan, Hui Li, Zhiqin Zhou, Lin Liu et al.
Biomedical Optics Express
Non-Invasive Vital Sign Monitoring
article

Detecting multiple fiducial markers from a camera seismocardiogram

Caifeng Shan, Hui Li, Zhiqin Zhou, Lin Liu, wenjin Wang
article en

Abstract

Seismocardiogram (SCG) records the cardiac contractions and valve functions, holding a promising avenue for the early detection of adverse cardiovascular events. To monitor such events, it is crucial to accurately identify the fiducial markers in the SCG signal in order to support the estimation of hemodynamic parameters. In this paper, we propose a novel framework that consists of a defocused camera-based speckle imaging system to measure the SCG signal and a deep learning based model (DiAT) to detect multiple fiducial markers. Specifically, DiAT employs dilated convolution and a multi-head attention mechanism to capture the temporal context of SCG signals for detecting seven fiducial markers (MC, IM, AO, IC, RE, AC, MO). The percentage of predicted values falling in the range of true values ± 1 ms, and the Mean Absolute Error (MAE) between the predicted value and the true value are used as evaluation metrics. Experiments involving 17 adult subjects with ice water stimulation protocol show that DiAT obtains 87.78% accuracy and 8.4106 ms MAE. It demonstrates that our proposed method has reliable performance in detecting seven fiducial markers of camera-SCG signals.

Biomedical Optics ExpressVol. 17(4)
Shandong University of Science and Technology (CN), Nanjing University (CN)
Climate action
Openalex Percentile: Top 43%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.