Integrating Coagulation and Flotation via Hydrodynamic Cavitation: The Key Role of Venturi Divergent Angle for Humic Substance Removal

Humic substances (HSs) pose a significant challenge to safe drinking-water production due to their ubiquity, limited removal by conventional methods, and their role in forming toxic disinfection by-products, reinforcing the need for more efficient, energy-favorable, and scalable treatment technologies. This study developed and evaluated a compact hydrodynamic cavitation (HC) system that simultaneously induces coagulation and generates microbubbles for flotation-based HS removal. For the first time, HC is explored as a multifunctional unit capable of integrating rapid mixing, coagulant destabilization, and flotation within a single device. Optimal coagulation conditions were established at pH 5.0 and 9.5 mg L−1 of ferric chloride. Process optimization using a Rotated Central Composite Design demonstrated that inlet pressure, flotation time, and initial HS concentration were the dominant operational factors, enabling the HC system to achieve a maximum removal efficiency of 81.9%. Five Venturi geometries with divergent angles of 4°, 8°, 11°, 14°, and 90° were investigated, with the 8° Venturi exhibiting superior performance due to stable microbubble formation and effective coagulant dispersion, as confirmed by CFD analyses. Comparative tests with a conventional Flotest unit showed that achieving similar efficiencies required at least 30% saturated water. In contrast, the HC system delivered equivalent removal in continuous flow without external air saturation. These findings demonstrate the potential of HC as an integrated coagulation–flotation core and highlight its promise as a compact, energy-efficient, and scalable technology for natural organic matter removal in water treatment.

Authors

Institutions

Publication Details

Journal
Clean Technologies
Published
2026-02-26
DOI
https://doi.org/10.3390/cleantechnol8020027
Primary Topic
Ultrasound and Cavitation Phenomena
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Integrating Coagulation and Flotation via Hydrodynamic Cavitation: The Key Role of Venturi Divergent Angle for Humic Substance Removal

Thiago Vinícius Ribeiro Soeira, Mario Sérgio Da Luz, André Luiz Andrade Simões, Marcos Vinícius Mateus et al.
Clean Technologies
Ultrasound and Cavitation Phenomena
article

Integrating Coagulation and Flotation via Hydrodynamic Cavitation: The Key Role of Venturi Divergent Angle for Humic Substance Removal

Thiago Vinícius Ribeiro Soeira, Mario Sérgio Da Luz, André Luiz Andrade Simões, Marcos Vinícius Mateus, Fausto de Souza Pagan, Julio Cesar de Souza Inacio Gonçalves, Deusmaque Carneiro Ferreira, Rodrigo Moruzzi
article en

Abstract

Humic substances (HSs) pose a significant challenge to safe drinking-water production due to their ubiquity, limited removal by conventional methods, and their role in forming toxic disinfection by-products, reinforcing the need for more efficient, energy-favorable, and scalable treatment technologies. This study developed and evaluated a compact hydrodynamic cavitation (HC) system that simultaneously induces coagulation and generates microbubbles for flotation-based HS removal. For the first time, HC is explored as a multifunctional unit capable of integrating rapid mixing, coagulant destabilization, and flotation within a single device. Optimal coagulation conditions were established at pH 5.0 and 9.5 mg L−1 of ferric chloride. Process optimization using a Rotated Central Composite Design demonstrated that inlet pressure, flotation time, and initial HS concentration were the dominant operational factors, enabling the HC system to achieve a maximum removal efficiency of 81.9%. Five Venturi geometries with divergent angles of 4°, 8°, 11°, 14°, and 90° were investigated, with the 8° Venturi exhibiting superior performance due to stable microbubble formation and effective coagulant dispersion, as confirmed by CFD analyses. Comparative tests with a conventional Flotest unit showed that achieving similar efficiencies required at least 30% saturated water. In contrast, the HC system delivered equivalent removal in continuous flow without external air saturation. These findings demonstrate the potential of HC as an integrated coagulation–flotation core and highlight its promise as a compact, energy-efficient, and scalable technology for natural organic matter removal in water treatment.

Clean TechnologiesVol. 8(2)
Universidade Federal da Bahia (BR), Universidade Federal de São Carlos (BR), Institute of Physics (PL), Universidade Federal do Triângulo Mineiro (BR), Universidade Estadual Paulista (Unesp) (BR)
Conselho Nacional de Desenvolvimento Científico e Tecnológico, Fundação de Amparo à Pesquisa do Estado de Minas Gerais
Clean water and sanitation
Openalex Percentile: Top 43%
Ultrasound and Cavitation Phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.