Multivariable Analysis of Indoor VOC Dynamics in a Smart Urban Building: Advancing Evidence-Based and Health-Centered Air Quality Management

This study investigates the dynamics of indoor volatile organic compounds (VOCs), including formaldehyde, xylene, and toluene, within a newly constructed smart urban building in Bangkok, Thailand. It aims to identify key determinants of air quality and to support datadriven strategies for healthier indoor environments. A total of 120 indoor air samples were collected from multiple zones and timeframes, considering building usage patterns, air conditioning operation, and environmental factors such as temperature, humidity, and air velocity. Statistical analyses revealed that air velocity and usage time significantly influenced VOC concentrations, while the time period was a critical factor for formaldehyde levels. Toluene concentrations exceeded the ACGIH guideline (20 ppm) in 13% of samples, and formaldehyde levels surpassed NIOSH thresholds in all samples, indicating potential exposure risks. Higher ventilation rates were linked to reduced pollutant accumulation, particularly during peak occupancy. Strong correlations between toluene and xylene also indicated shared emission sources. Although most values remained within regulatory limits, some exceeded health-based guidelines. These findings highlight the complex interactions among building operations, environmental conditions, and chemical exposure, and suggest targeted ventilation scheduling, particularly early-morning activation, to reduce VOC peaks. The study provides a practical framework for designing adaptive ventilation systems and developing guidelines to improve indoor air quality in new buildings. Insights from this research can inform future policy, urban planning, and smart building design aimed at reducing health risks and enhancing environmental resilience.

Authors

Institutions

Publication Details

Journal
Nature Environment and Pollution Technology
Published
2026-02-26
DOI
https://doi.org/10.46488/nept.2026.v25i01.d1832
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multivariable Analysis of Indoor VOC Dynamics in a Smart Urban Building: Advancing Evidence-Based and Health-Centered Air Quality Management

Nuchcha Phonphoton, Chotirot Thonotue, Suwat Suksawatdi
Nature Environment and Pollution Technology
Indoor Air Quality and Microbial Exposure
article

Multivariable Analysis of Indoor VOC Dynamics in a Smart Urban Building: Advancing Evidence-Based and Health-Centered Air Quality Management

Nuchcha Phonphoton, Chotirot Thonotue, Suwat Suksawatdi
article en

Abstract

This study investigates the dynamics of indoor volatile organic compounds (VOCs), including formaldehyde, xylene, and toluene, within a newly constructed smart urban building in Bangkok, Thailand. It aims to identify key determinants of air quality and to support datadriven strategies for healthier indoor environments. A total of 120 indoor air samples were collected from multiple zones and timeframes, considering building usage patterns, air conditioning operation, and environmental factors such as temperature, humidity, and air velocity. Statistical analyses revealed that air velocity and usage time significantly influenced VOC concentrations, while the time period was a critical factor for formaldehyde levels. Toluene concentrations exceeded the ACGIH guideline (20 ppm) in 13% of samples, and formaldehyde levels surpassed NIOSH thresholds in all samples, indicating potential exposure risks. Higher ventilation rates were linked to reduced pollutant accumulation, particularly during peak occupancy. Strong correlations between toluene and xylene also indicated shared emission sources. Although most values remained within regulatory limits, some exceeded health-based guidelines. These findings highlight the complex interactions among building operations, environmental conditions, and chemical exposure, and suggest targeted ventilation scheduling, particularly early-morning activation, to reduce VOC peaks. The study provides a practical framework for designing adaptive ventilation systems and developing guidelines to improve indoor air quality in new buildings. Insights from this research can inform future policy, urban planning, and smart building design aimed at reducing health risks and enhancing environmental resilience.

Nature Environment and Pollution TechnologyVol. 25(1)
Navamindradhiraj University (TH)
Sustainable cities and communities
Openalex Percentile: Top 47%
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.