Study on Pantograph–Rigid Catenary Separation Through Simulation Experiments and the Dynamic Characteristics of DC Arcs

The pantograph–catenary system is a critical component of the traction power supply network. Due to hard points on the overhead contact line and vibrations of the pantograph, pantograph–catenary separation may occur, leading to offline DC arc events. To investigate the characteristics of DC arcs generated during pantograph–catenary separation in metro systems, this study constructs a laboratory platform that simulates the offline process and analyzes the electrical characteristics, optical intensity, and arc-burn duration under different electrode separation conditions. First, a DC pantograph–catenary offline arc simulation platform is developed using a contact wire, a carbon-strip pantograph slider, and a linear motor, enabling slider movement in both horizontal and vertical directions. Second, offline discharge experiments are conducted to compare the discharge process and electrical arc characteristics with and without horizontal slider motion. Finally, arc luminosity and burn duration are measured under various electrode separation configurations, and the influence of voltage level, current level, and electrode material is examined. Experimental results reveal a significant polarity effect, where the arc burn duration is notably longer when the contact wire serves as the cathode than when the carbon slider serves as the cathode. At the instant of separation, the high electric field intensity within the micro-gap triggers pronounced “peak phenomena” in both arc resistance and power, accompanied by abrupt voltage surges and transient current dips. Furthermore, the introduction of horizontal motion modulates the arcing process, causing the stable arcing voltage to follow a distinctive trend of a slow increase followed by a gradual decrease, which differs from static separation characteristics. Finally, this study demonstrates that voltage levels exert a more dominant influence on arc luminosity and duration than current levels, while the maintenance voltage of the arc channel remains significantly lower than the air breakdown voltage.

Authors

Institutions

Publication Details

Journal
Machines
Published
2026-02-26
DOI
https://doi.org/10.3390/machines14030264
Primary Topic
Electrical Contact Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on Pantograph–Rigid Catenary Separation Through Simulation Experiments and the Dynamic Characteristics of DC Arcs

Guangxiao Wang, Zhaofeng Gong, Shuai Xu, Guangjian Zhang et al.
Machines
Electrical Contact Performance and Analysis
article

Study on Pantograph–Rigid Catenary Separation Through Simulation Experiments and the Dynamic Characteristics of DC Arcs

Guangxiao Wang, Zhaofeng Gong, Shuai Xu, Guangjian Zhang, Chang Liu, Wenzheng Liu
article en

Abstract

The pantograph–catenary system is a critical component of the traction power supply network. Due to hard points on the overhead contact line and vibrations of the pantograph, pantograph–catenary separation may occur, leading to offline DC arc events. To investigate the characteristics of DC arcs generated during pantograph–catenary separation in metro systems, this study constructs a laboratory platform that simulates the offline process and analyzes the electrical characteristics, optical intensity, and arc-burn duration under different electrode separation conditions. First, a DC pantograph–catenary offline arc simulation platform is developed using a contact wire, a carbon-strip pantograph slider, and a linear motor, enabling slider movement in both horizontal and vertical directions. Second, offline discharge experiments are conducted to compare the discharge process and electrical arc characteristics with and without horizontal slider motion. Finally, arc luminosity and burn duration are measured under various electrode separation configurations, and the influence of voltage level, current level, and electrode material is examined. Experimental results reveal a significant polarity effect, where the arc burn duration is notably longer when the contact wire serves as the cathode than when the carbon slider serves as the cathode. At the instant of separation, the high electric field intensity within the micro-gap triggers pronounced “peak phenomena” in both arc resistance and power, accompanied by abrupt voltage surges and transient current dips. Furthermore, the introduction of horizontal motion modulates the arcing process, causing the stable arcing voltage to follow a distinctive trend of a slow increase followed by a gradual decrease, which differs from static separation characteristics. Finally, this study demonstrates that voltage levels exert a more dominant influence on arc luminosity and duration than current levels, while the maintenance voltage of the arc channel remains significantly lower than the air breakdown voltage.

MachinesVol. 14(3)
Beijing Jiaotong University (CN)
Openalex Percentile: Top 43%
Electrical Contact Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.