Slowly absorbable suture for fascial defect closure in open incisional hernia mesh-repair is associated with decreased long-term recurrence: a nationwide cohort study

Recurrence after incisional hernia repair is an important outcome measure with rates still ranging high. For open incisional hernia repair a mesh-based technique with fascial defect closure is recommended, but there is no evidence supporting the choice of suture used for the defect closure. Slowly absorbable suture has been advised as reducing the risk of primary incisional hernia formation after abdominal surgery, but whether this applies as best choice compared to non-absorbable suture in open incisional hernia repair with mesh is undetermined. This was a nationwide registry study with a 100% follow-up from 2007 to 2022. Eligibility criteria were elective open incisional hernia surgery, mesh-based technique, and fascial defect closure with slowly absorbable or non-absorbable suture. The 5-year cumulative incidence of reoperation for hernia recurrence was determined. Confounders were included in multivariate regression analyses. A total of 3393 patients were included. Mean (sd) age was 60.6 (13) years and 50% were females. Mean horizontal defect size was 6.4 (4.7) cm and 1900 (56%) patients had vertical incisions. Incidence of 90-day surgical reintervention was 143 (4.2%). Median (IQR) follow-up was 3.5 (1.6–3.8) years, and 249 (7.3%) patients underwent operation for recurrence. Cox regression analysis showed that non-absorbable suture was associated with a significantly increased risk of operation for recurrence compared to slowly absorbable (HR 1.33, CI 1.01–1.76, P = 0.043). Type of suture was not associated with increased risk of 90-day reoperation. Using a slowly absorbable suture for fascial closure is associated with a decreased risk of long-term hernia recurrence compared to non-absorbable suture after open incisional hernia mesh-repair.

Authors

Institutions

Publication Details

Journal
Hernia
Published
2026-02-26
DOI
https://doi.org/10.1007/s10029-026-03585-y
Primary Topic
Hernia repair and management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Slowly absorbable suture for fascial defect closure in open incisional hernia mesh-repair is associated with decreased long-term recurrence: a nationwide cohort study

Mads Marckmann, Nadia A. Henriksen, Mette Christoffersen, Kristian Schaumburg Kiim
Hernia
Hernia repair and management
article

Slowly absorbable suture for fascial defect closure in open incisional hernia mesh-repair is associated with decreased long-term recurrence: a nationwide cohort study

Mads Marckmann, Nadia A. Henriksen, Mette Christoffersen, Kristian Schaumburg Kiim
article en

Abstract

Recurrence after incisional hernia repair is an important outcome measure with rates still ranging high. For open incisional hernia repair a mesh-based technique with fascial defect closure is recommended, but there is no evidence supporting the choice of suture used for the defect closure. Slowly absorbable suture has been advised as reducing the risk of primary incisional hernia formation after abdominal surgery, but whether this applies as best choice compared to non-absorbable suture in open incisional hernia repair with mesh is undetermined. This was a nationwide registry study with a 100% follow-up from 2007 to 2022. Eligibility criteria were elective open incisional hernia surgery, mesh-based technique, and fascial defect closure with slowly absorbable or non-absorbable suture. The 5-year cumulative incidence of reoperation for hernia recurrence was determined. Confounders were included in multivariate regression analyses. A total of 3393 patients were included. Mean (sd) age was 60.6 (13) years and 50% were females. Mean horizontal defect size was 6.4 (4.7) cm and 1900 (56%) patients had vertical incisions. Incidence of 90-day surgical reintervention was 143 (4.2%). Median (IQR) follow-up was 3.5 (1.6–3.8) years, and 249 (7.3%) patients underwent operation for recurrence. Cox regression analysis showed that non-absorbable suture was associated with a significantly increased risk of operation for recurrence compared to slowly absorbable (HR 1.33, CI 1.01–1.76, P = 0.043). Type of suture was not associated with increased risk of 90-day reoperation. Using a slowly absorbable suture for fascial closure is associated with a decreased risk of long-term hernia recurrence compared to non-absorbable suture after open incisional hernia mesh-repair.

HerniaVol. 30(1)
Bispebjerg Hospital (DK), Copenhagen University Hospital (DK), Rigshospitalet (DK), Zealand University Hospital (DK), Zealand University Hospital Køge (DK)
Good health and well-being
Openalex Percentile: Top 42%
Hernia repair and management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.