Accuracy analysis of optical-based measurements considering distance, height, and temperature variations

Refraction is one of the most important factors affecting the accuracy of optical and electromagnetic measurement systems. In this study, the effect of refraction on measurement accuracy was investigated by processing video camera images obtained under different distances, temperatures, and object height conditions. Video camera recordings directed at a fixed target were processed using the Template Matching method in MATLAB. The normalized cross correlation (NCC) algorithm was used to prevent the effects of brightness or contrast differences and to ensure a more reliable comparison. A time series of target position changes (caused by refraction) was obtained, and the results were interpreted using statistical measures such as standard deviation (σ) and the F-test. The findings showed that the σ increased as distance and temperature increased, while the deviation decreased as the target height increased. Furthermore, the deviations of the horizontal component were found to be higher than those of the vertical component. For the first measurement, the deviations varied between ±0.3 and ±4.50 mm, depending on temperature and distance. In the second measurement, the deviation increased to ±6.8 mm when the measured object was 0.50 m above the ground, but decreased to ±2.6 mm at a height of 2.50 m. The deviation values ​​obtained in the current study are not a problem for applications where a few centimeters of precision are sufficient in rough construction work. However, in applications requiring high precision, such as industrial measurements and deformation monitoring, refraction effects must be considered. The pressure factor was not investigated in this study, and future studies are recommended to evaluate the contribution of each parameter to refraction separately.

Authors

Institutions

Publication Details

Journal
Journal of King Saud University - Science
Published
2026-02-26
DOI
https://doi.org/10.25259/jksus_1408_2025
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy analysis of optical-based measurements considering distance, height, and temperature variations

Mehmet Eren
Journal of King Saud University - Science
Optical measurement and interference techniques
article

Accuracy analysis of optical-based measurements considering distance, height, and temperature variations

Mehmet Eren
article en

Abstract

Refraction is one of the most important factors affecting the accuracy of optical and electromagnetic measurement systems. In this study, the effect of refraction on measurement accuracy was investigated by processing video camera images obtained under different distances, temperatures, and object height conditions. Video camera recordings directed at a fixed target were processed using the Template Matching method in MATLAB. The normalized cross correlation (NCC) algorithm was used to prevent the effects of brightness or contrast differences and to ensure a more reliable comparison. A time series of target position changes (caused by refraction) was obtained, and the results were interpreted using statistical measures such as standard deviation (σ) and the F-test. The findings showed that the σ increased as distance and temperature increased, while the deviation decreased as the target height increased. Furthermore, the deviations of the horizontal component were found to be higher than those of the vertical component. For the first measurement, the deviations varied between ±0.3 and ±4.50 mm, depending on temperature and distance. In the second measurement, the deviation increased to ±6.8 mm when the measured object was 0.50 m above the ground, but decreased to ±2.6 mm at a height of 2.50 m. The deviation values ​​obtained in the current study are not a problem for applications where a few centimeters of precision are sufficient in rough construction work. However, in applications requiring high precision, such as industrial measurements and deformation monitoring, refraction effects must be considered. The pressure factor was not investigated in this study, and future studies are recommended to evaluate the contribution of each parameter to refraction separately.

Journal of King Saud University - ScienceVol. 38
Yıldız Technical University (TR)
Openalex Percentile: Top 44%
Optical measurement and interference techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.