Attenuation correction of cardiac 82Rb pet using deep learning generated synthetic CT

Ischemic heart disease remains a leading cause of mortality worldwide. Myocardial perfusion imaging (MPI) using Rubidium-82 (<sup>82</sup>Rb) positron emission tomography (PET) is a cornerstone in its evaluation. However, conventional CT-based attenuation correction (AC) is prone to artifacts, with misalignment between PET emission data and the CT-AC being a common problem. This study evaluates the feasibility of introducing a deep learning approach to generate synthetic CT (sCT) images directly from non-attenuation-corrected <sup>82</sup>Rb-PET images. To this end, we developed a cGAN using a conditional generative adversarial network (cGAN) with an Attention U-Net generator to produce sCT images to produce sCT-AC maps, based upon 544 PET/CT MPI scans. Image quality was assessed using structural similarity index (SSIM), peak signal-to-noise ratio (PSNR), mean absolute error (MAE), and mean error (ME). Additionally, attenuation-corrected PET images based on sCT were evaluated in the cardiac region using relative mean error (RME) and relative mean absolute error (RMAE). Cardiac function and perfusion assessments, defined as the ischemic total perfusion deficit (iTPD) and the left ventricular ejection fraction reserve (LVEFR), were compared between sCT-based and conventional CT AC methods. Our sCT-images provided good correlation to the conventional CT-AC (SSIM = 0.91 ± 0.037, PSNR = 29.9 ± 3.2 dB). For the PET images, we report a slight bias in the cardiac region (RME = 4.2 ± 7.8%, RMAE = 6.9 ± 5.9%), likely due to a uniform overestimation of the soft-tissue u-maps within the sCT. Despite the bias, the quantification metrics remained comparable to those obtained with CT AC (mean iTPD: CT 3.73 ± 5.19% vs. sCT 3.67 ± 5.13%; mean LVEFR: CT 5.88 ± 5.96% vs. sCT 5.90 ± 6.11%). Additionally, the sCT-based approach appeared to reduce motion and implant-related artifacts, providing further motivation for its use over CT. This observation was made through visual inspection on a case-by-case basis. These results demonstrate the potential of deep learning-based sCT generation to maintain integrity in PET MPI while helping to mitigate issues related to misalignments and metal-induced artifacts.

Authors

Institutions

Publication Details

Journal
EJNMMI Physics
Published
2026-02-26
DOI
https://doi.org/10.1186/s40658-026-00849-5
Primary Topic
Cardiac Imaging and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Attenuation correction of cardiac 82Rb pet using deep learning generated synthetic CT

Philip Hasbak, Martin Lyngby Lassen, Claes Nøhr Ladefoged, Kasper Jørgensen et al.
EJNMMI Physics
Cardiac Imaging and Diagnostics
article

Attenuation correction of cardiac 82Rb pet using deep learning generated synthetic CT

Philip Hasbak, Martin Lyngby Lassen, Claes Nøhr Ladefoged, Kasper Jørgensen, Flemming Littrup Andersen
article en

Abstract

Ischemic heart disease remains a leading cause of mortality worldwide. Myocardial perfusion imaging (MPI) using Rubidium-82 (<sup>82</sup>Rb) positron emission tomography (PET) is a cornerstone in its evaluation. However, conventional CT-based attenuation correction (AC) is prone to artifacts, with misalignment between PET emission data and the CT-AC being a common problem. This study evaluates the feasibility of introducing a deep learning approach to generate synthetic CT (sCT) images directly from non-attenuation-corrected <sup>82</sup>Rb-PET images. To this end, we developed a cGAN using a conditional generative adversarial network (cGAN) with an Attention U-Net generator to produce sCT images to produce sCT-AC maps, based upon 544 PET/CT MPI scans. Image quality was assessed using structural similarity index (SSIM), peak signal-to-noise ratio (PSNR), mean absolute error (MAE), and mean error (ME). Additionally, attenuation-corrected PET images based on sCT were evaluated in the cardiac region using relative mean error (RME) and relative mean absolute error (RMAE). Cardiac function and perfusion assessments, defined as the ischemic total perfusion deficit (iTPD) and the left ventricular ejection fraction reserve (LVEFR), were compared between sCT-based and conventional CT AC methods. Our sCT-images provided good correlation to the conventional CT-AC (SSIM = 0.91 ± 0.037, PSNR = 29.9 ± 3.2 dB). For the PET images, we report a slight bias in the cardiac region (RME = 4.2 ± 7.8%, RMAE = 6.9 ± 5.9%), likely due to a uniform overestimation of the soft-tissue u-maps within the sCT. Despite the bias, the quantification metrics remained comparable to those obtained with CT AC (mean iTPD: CT 3.73 ± 5.19% vs. sCT 3.67 ± 5.13%; mean LVEFR: CT 5.88 ± 5.96% vs. sCT 5.90 ± 6.11%). Additionally, the sCT-based approach appeared to reduce motion and implant-related artifacts, providing further motivation for its use over CT. This observation was made through visual inspection on a case-by-case basis. These results demonstrate the potential of deep learning-based sCT generation to maintain integrity in PET MPI while helping to mitigate issues related to misalignments and metal-induced artifacts.

EJNMMI Physics
University of Copenhagen (DK), Rigshospitalet (DK), Technical University of Denmark (DK)
Good health and well-being
Openalex Percentile: Top 43%
Cardiac Imaging and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.