Study of the Response Time and Sensitivity of the MG-32 Pyroelectric Detector with a Polypropylene Window in the Visible Range

The response time and sensitivity in the visible spectral range of a commercial MG-32 pyroelectric detector based on the organic crystal of tetraaminodiphenyl (NZPP Vostok JSC) with a 0.5 mm thick polypropylene input window are studied. The sensor time constant is varied by connecting a capacitance $$C$$ in the range from 2 nF to 3.8 $$\mu$$ F to the feedback circuit of the receiver amplifier. With increasing capacitance in the range of 0.1–3.8 $$\mu$$ F, the receiver time constant increased linearly from 0.2 to 5 ms, and at lower capacitances it reached saturation, setting a limit of $$\approx$$ 25 $$\mu$$ s. The voltage sensitivity is tested using a diode laser ( $$\lambda=637$$ nm); at $$C=0{.}1$$ $$\mu$$ F, it is 3600 V W $${}^{-1}$$ , which is 8 $$\%$$ less than the sensitivity of the receiver without a polypropylene window. The equivalent noise power is virtually independent of the feedback capacitance in the range of $$C=0{.}002{-}0{.}1$$ $$\mu$$ F and is $$0{.}8\times 10^{-10}$$ W Hz $${}^{-1/2}$$ , while the detectivity is $$10^{9}$$ cm W Hz $${}^{-1/2}$$ . These characteristics are approximately one or two orders of magnitude superior to those of other commercial pyroelectric detectors and the Golay optoacoustic cell, making the receiver under study quite promising and versatile for many applications.

Authors

Institutions

Publication Details

Journal
Optoelectronics Instrumentation and Data Processing
Published
2025-10-01
DOI
https://doi.org/10.3103/s8756699025700748
Primary Topic
Photorefractive and Nonlinear Optics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study of the Response Time and Sensitivity of the MG-32 Pyroelectric Detector with a Polypropylene Window in the Visible Range

V. V. Gerasimov, D. V. Fromichev, G. R. Turkiya, S. E. Krasnopevtsev et al.
Optoelectronics Instrumentation and Data Processing
Photorefractive and Nonlinear Optics
article

Study of the Response Time and Sensitivity of the MG-32 Pyroelectric Detector with a Polypropylene Window in the Visible Range

V. V. Gerasimov, D. V. Fromichev, G. R. Turkiya, S. E. Krasnopevtsev, V. A. Stepanov
article en

Abstract

The response time and sensitivity in the visible spectral range of a commercial MG-32 pyroelectric detector based on the organic crystal of tetraaminodiphenyl (NZPP Vostok JSC) with a 0.5 mm thick polypropylene input window are studied. The sensor time constant is varied by connecting a capacitance $$C$$ in the range from 2 nF to 3.8 $$\mu$$ F to the feedback circuit of the receiver amplifier. With increasing capacitance in the range of 0.1–3.8 $$\mu$$ F, the receiver time constant increased linearly from 0.2 to 5 ms, and at lower capacitances it reached saturation, setting a limit of $$\approx$$ 25 $$\mu$$ s. The voltage sensitivity is tested using a diode laser ( $$\lambda=637$$ nm); at $$C=0{.}1$$ $$\mu$$ F, it is 3600 V W $${}^{-1}$$ , which is 8 $$\%$$ less than the sensitivity of the receiver without a polypropylene window. The equivalent noise power is virtually independent of the feedback capacitance in the range of $$C=0{.}002{-}0{.}1$$ $$\mu$$ F and is $$0{.}8\times 10^{-10}$$ W Hz $${}^{-1/2}$$ , while the detectivity is $$10^{9}$$ cm W Hz $${}^{-1/2}$$ . These characteristics are approximately one or two orders of magnitude superior to those of other commercial pyroelectric detectors and the Golay optoacoustic cell, making the receiver under study quite promising and versatile for many applications.

Optoelectronics Instrumentation and Data ProcessingVol. 61(5)
Novosibirsk State University (RU), Research Institute of Semiconductor Devices (RU), Budker Institute of Nuclear Physics (RU)
Affordable and clean energy
Openalex Percentile: Top 27%
Photorefractive and Nonlinear Optics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.