Influence of Carbon Dioxide and pH on Influenza Virus in Sessile Saliva Droplets

Upon exhalation, virus-laden respiratory droplets experience rapid changes in environmental conditions that lead to chemical and physical alterations that can affect virus infectivity. By manipulating the concentration of gaseous carbon dioxide (CO<sub>2</sub>) surrounding sessile saliva droplets, we altered their chemistry and then assessed the impacts of these changes on the infectivity of influenza A virus at relative humidities of 30, 50, and 80%. For virus exposed to low CO<sub>2</sub> (<0.005% CO<sub>2</sub> in N<sub>2</sub>) vs high CO<sub>2</sub> (4.3-5% CO<sub>2</sub> in N<sub>2</sub>), differences in inactivation were small except at 80% RH, where the virus decayed less (i.e., maintained greater infectivity) in low CO<sub>2</sub> than in high CO<sub>2</sub>. The difference exceeded 1log<sub>10</sub> at 2 h. For comparison, virus inactivation in ambient air (0.04% CO<sub>2</sub>) varied across conditions, sometimes exceeding and sometimes falling below that observed under high- and low-CO<sub>2</sub> atmospheres. Collectively, these results suggest that the driving factors for virus inactivation vary with RH. We measured droplet pH using gold nanoprobes in combination with surface-enhanced Raman spectroscopy and found that pH increased in low CO<sub>2</sub> and decreased in high CO<sub>2</sub> at 80% RH by ∼1 pH unit in both cases. Results were consistent with chemical equilibrium modeling, which indicated that both carbonate and phosphate buffering were important. Changes in pH were smaller or insignificant at 30 and 55% RH. At these low and medium RHs, rapid evaporation of water from the droplets and the resulting increase in viscosity may limit changes in pH. Measured changes in pH did not appear to be sufficient to drive virus inactivation under any tested condition. This finding suggests that pH likely does not impact influenza transmission by fomites.

Authors

Institutions

Publication Details

Journal
Environmental Science & Technology
Published
2026-02-26
DOI
https://doi.org/10.1021/acs.est.5c12672
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of Carbon Dioxide and pH on Influenza Virus in Sessile Saliva Droplets

Linsey C. Marr, Liviana K. Klein, Alexandra Longest, Peter J. Vikesland et al.
Environmental Science & Technology
Infection Control and Ventilation
article

Influence of Carbon Dioxide and pH on Influenza Virus in Sessile Saliva Droplets

Linsey C. Marr, Liviana K. Klein, Alexandra Longest, Peter J. Vikesland, Nisha K. Duggal, Frank A. Mazzola, Rania E. Smeltz, Jeffrey L. Parks, Sonali Srivastava
article en

Abstract

Upon exhalation, virus-laden respiratory droplets experience rapid changes in environmental conditions that lead to chemical and physical alterations that can affect virus infectivity. By manipulating the concentration of gaseous carbon dioxide (CO<sub>2</sub>) surrounding sessile saliva droplets, we altered their chemistry and then assessed the impacts of these changes on the infectivity of influenza A virus at relative humidities of 30, 50, and 80%. For virus exposed to low CO<sub>2</sub> (<0.005% CO<sub>2</sub> in N<sub>2</sub>) vs high CO<sub>2</sub> (4.3-5% CO<sub>2</sub> in N<sub>2</sub>), differences in inactivation were small except at 80% RH, where the virus decayed less (i.e., maintained greater infectivity) in low CO<sub>2</sub> than in high CO<sub>2</sub>. The difference exceeded 1log<sub>10</sub> at 2 h. For comparison, virus inactivation in ambient air (0.04% CO<sub>2</sub>) varied across conditions, sometimes exceeding and sometimes falling below that observed under high- and low-CO<sub>2</sub> atmospheres. Collectively, these results suggest that the driving factors for virus inactivation vary with RH. We measured droplet pH using gold nanoprobes in combination with surface-enhanced Raman spectroscopy and found that pH increased in low CO<sub>2</sub> and decreased in high CO<sub>2</sub> at 80% RH by ∼1 pH unit in both cases. Results were consistent with chemical equilibrium modeling, which indicated that both carbonate and phosphate buffering were important. Changes in pH were smaller or insignificant at 30 and 55% RH. At these low and medium RHs, rapid evaporation of water from the droplets and the resulting increase in viscosity may limit changes in pH. Measured changes in pH did not appear to be sufficient to drive virus inactivation under any tested condition. This finding suggests that pH likely does not impact influenza transmission by fomites.

Environmental Science & TechnologyVol. 60(9)
Virginia–Maryland College of Veterinary Medicine (US), Institute of Biomedical Sciences, Academia Sinica (TW), Institute of Biomedical Science (GB), Virginia Tech (US)
Life in Land
Openalex Percentile: Top 42%
Infection Control and Ventilation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.