In Vitro Thrombogenicity Evaluation of Hemodialyzers

Investigation of dialyzer thrombogenicity is a critical step during the development of a new dialyzer. Novel dialyzer membranes aim to reduce the inherent thrombogenic potential of artificial surfaces by, e.g., increasing membrane hydrophilicity. Reliable in vitro testing is fundamental during dialyzer development and must be in line with the current standards. Using the novel FX CorAL dialyzer with its increased membrane hydrophilicity as an example, this study characterizes dialyzer thrombogenicity in an in vitro test setup in line with ISO 10993-4 and identifies factors which influence dialyzer thrombogenicity. In a recirculation setup with human blood, platelet activation (platelet counts, β-thromboglobulin, platelet adsorption), coagulation (thrombin-antithrombin III complex) and complement activation (sC5b-9) were investigated among polysulfone- (FX CorAL, FX CorDiax, Optiflux, xevonta), polyethersulfone- (ELISIO, Revaclear, Theranova) and AN69 ST-based (Nephral) dialyzers. Additionally, the impact of dialysate and electrolyte composition on thrombogenicity was investigated. The FX CorAL showed the lowest platelet activation compared to all poly(ether)sulfone-based dialyzers and lower complement activation compared to most poly(ether)sulfone-based dialyzers and to the Nephral dialyzer. No significant differences were observed between the investigated dialyzers with regard to plasmatic coagulation. Among the tested parameters, the dialyzer showed the strongest impact on the thrombogenicity results. This study proposes guidance on in vitro testing of dialyzer thrombogenicity in line with current standards and may contribute to reducing the current heterogeneity among in vitro hemocompatibility testing.

Authors

Institutions

Publication Details

Journal
International Journal of Molecular Sciences
Published
2026-02-25
DOI
https://doi.org/10.3390/ijms27052164
Primary Topic
Dialysis and Renal Disease Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In Vitro Thrombogenicity Evaluation of Hemodialyzers

Adam M. Zawada, Nathan Crook, Robert Nitschel, Ansgar Erlenkoetter et al.
International Journal of Molecular Sciences
Dialysis and Renal Disease Management
article

In Vitro Thrombogenicity Evaluation of Hemodialyzers

Adam M. Zawada, Nathan Crook, Robert Nitschel, Ansgar Erlenkoetter, Craig D. Kamerath, Skyler Boyington
article en

Abstract

Investigation of dialyzer thrombogenicity is a critical step during the development of a new dialyzer. Novel dialyzer membranes aim to reduce the inherent thrombogenic potential of artificial surfaces by, e.g., increasing membrane hydrophilicity. Reliable in vitro testing is fundamental during dialyzer development and must be in line with the current standards. Using the novel FX CorAL dialyzer with its increased membrane hydrophilicity as an example, this study characterizes dialyzer thrombogenicity in an in vitro test setup in line with ISO 10993-4 and identifies factors which influence dialyzer thrombogenicity. In a recirculation setup with human blood, platelet activation (platelet counts, β-thromboglobulin, platelet adsorption), coagulation (thrombin-antithrombin III complex) and complement activation (sC5b-9) were investigated among polysulfone- (FX CorAL, FX CorDiax, Optiflux, xevonta), polyethersulfone- (ELISIO, Revaclear, Theranova) and AN69 ST-based (Nephral) dialyzers. Additionally, the impact of dialysate and electrolyte composition on thrombogenicity was investigated. The FX CorAL showed the lowest platelet activation compared to all poly(ether)sulfone-based dialyzers and lower complement activation compared to most poly(ether)sulfone-based dialyzers and to the Nephral dialyzer. No significant differences were observed between the investigated dialyzers with regard to plasmatic coagulation. Among the tested parameters, the dialyzer showed the strongest impact on the thrombogenicity results. This study proposes guidance on in vitro testing of dialyzer thrombogenicity in line with current standards and may contribute to reducing the current heterogeneity among in vitro hemocompatibility testing.

International Journal of Molecular SciencesVol. 27(5)
Fresenius Medical Care (United States) (US), Fresenius Medical Care North America (United States) (US), Fresenius Medical Care (Germany) (DE)
Life below water
Openalex Percentile: Top 50%
Dialysis and Renal Disease Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.