Genetic Algorithm-Based Dynamic Volt–VAR Control Using D-STATCOM for Voltage Profile Enhancement in Distribution Systems

This paper proposes a quasi-dynamic Volt–Var control strategy for radial distribution networks based on the optimal sizing of a distribution static synchronous compensator (D-STATCOM) using a genetic algorithm (GA). The objective is to enhance voltage regulation and reduce technical energy losses under variable loading conditions while preserving nonlinear AC power flow fidelity. The IEEE 33-bus test system was modeled in DIgSILENT PowerFactory (v2021), and the D-STATCOM installation bus was selected based on a rigorous literature-supported placement criterion derived from optimization-based studies. Three representative demand scenarios—minimum, average, and maximum loading—were defined to approximate quasi-dynamic operation over a daily cycle. The GA was implemented in MATLAB (R2023b) to solve a normalized nonlinear multi-objective optimization problem that simultaneously minimizes total active power losses and the aggregate voltage deviation index. The optimized reactive power capacities obtained were 0.49 Mvar, 1.1933 Mvar, and 2.30 Mvar for the minimum, average, and maximum demand scenarios, respectively. These configurations achieved active power loss reductions of 27.5%, 24.602%, and 23.44% under the corresponding loading levels while improving voltage regulation at the critical bus (bus 18) and maintaining system voltages within the admissible 0.95–1.05 p.u. range. Through quasi-dynamic interpolation of operating points, the daily performance assessment showed a 24.11% reduction in total energy losses and a 38.28% decrease in the average voltage deviation. A statistical robustness analysis confirmed stable convergence behavior across independent executions. The results demonstrate that the proposed framework provides a computationally efficient, planning-oriented approach for reactive power compensation in distribution systems subject to demand variability.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-02-26
DOI
https://doi.org/10.3390/en19051170
Primary Topic
Optimal Power Flow Distribution
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Genetic Algorithm-Based Dynamic Volt–VAR Control Using D-STATCOM for Voltage Profile Enhancement in Distribution Systems

Wilmer Fernando Tituaña Toapanta, Alexander Águila Téllez
Energies
Optimal Power Flow Distribution
article

Genetic Algorithm-Based Dynamic Volt–VAR Control Using D-STATCOM for Voltage Profile Enhancement in Distribution Systems

Wilmer Fernando Tituaña Toapanta, Alexander Águila Téllez
article en

Abstract

This paper proposes a quasi-dynamic Volt–Var control strategy for radial distribution networks based on the optimal sizing of a distribution static synchronous compensator (D-STATCOM) using a genetic algorithm (GA). The objective is to enhance voltage regulation and reduce technical energy losses under variable loading conditions while preserving nonlinear AC power flow fidelity. The IEEE 33-bus test system was modeled in DIgSILENT PowerFactory (v2021), and the D-STATCOM installation bus was selected based on a rigorous literature-supported placement criterion derived from optimization-based studies. Three representative demand scenarios—minimum, average, and maximum loading—were defined to approximate quasi-dynamic operation over a daily cycle. The GA was implemented in MATLAB (R2023b) to solve a normalized nonlinear multi-objective optimization problem that simultaneously minimizes total active power losses and the aggregate voltage deviation index. The optimized reactive power capacities obtained were 0.49 Mvar, 1.1933 Mvar, and 2.30 Mvar for the minimum, average, and maximum demand scenarios, respectively. These configurations achieved active power loss reductions of 27.5%, 24.602%, and 23.44% under the corresponding loading levels while improving voltage regulation at the critical bus (bus 18) and maintaining system voltages within the admissible 0.95–1.05 p.u. range. Through quasi-dynamic interpolation of operating points, the daily performance assessment showed a 24.11% reduction in total energy losses and a 38.28% decrease in the average voltage deviation. A statistical robustness analysis confirmed stable convergence behavior across independent executions. The results demonstrate that the proposed framework provides a computationally efficient, planning-oriented approach for reactive power compensation in distribution systems subject to demand variability.

EnergiesVol. 19(5)
Politecnica Salesiana University (EC)
Universidad Politécnica Salesiana del Ecuador
Affordable and clean energy
Openalex Percentile: Top 44%
Optimal Power Flow Distribution
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.