Wear resistance, microhardness and compressive strength of high filled flowable composite resins

This in vitro study evaluated microhardness, compressive strength, and wear resistance of seven composite resins: six high-filled flowable and one conventional resin. A total of 140 specimens were prepared from seven composite resins (n = 20). The materials tested included Omnichroma Flow (OCF), Vittra Unique Flow (VUF), Estelite Universal Flow High (EUFH), Medium (EUFM), Superlow (EUFS), Genial Injectable (GUIN), and Filtek Z250 (FZ250). Wear resistance was measured on cylindrical specimens (12 mm × 2 mm ) using a reciprocating tribometer with a Al₂O₃ antagonist, 20 N load, 1 mm stroke, 2.5 mm/s speed, and 1500 cycles. Compressive strength was tested on cylindrical specimens (4 mm × 6 mm) with a universal testing machine at 0.5 mm/min crosshead speed. Vickers microhardness was measured on disc specimens (2 mm × 8 mm) with a 100 g load for 10 s. One-way ANOVA and Tukey HSD tests (p < 0.05) were used for statistical analysis. EUFH, VUF, and OCF had significantly higher wear volumes than FZ250. FZ250 had greater microhardness than all high-filled flowable composites. Although the compressive strength values of the tested high-filled flowable composites were similar to that of the conventional composite resin, variations were observed among the flowable composites themselves. Under the conditions of this in vitro study, high-filled flowable composites showed comparable compressive strength to a conventional composite resin but tended to exhibit higher wear and lower surface hardness, which should be considered when selecting materials for stress-bearing restorations.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-02-26
DOI
https://doi.org/10.1038/s41598-026-41928-y
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wear resistance, microhardness and compressive strength of high filled flowable composite resins

Seyit Bilal Özdemir, Busra Ozdemir
Scientific Reports
Dental materials and restorations
article

Wear resistance, microhardness and compressive strength of high filled flowable composite resins

Seyit Bilal Özdemir, Busra Ozdemir
article en

Abstract

This in vitro study evaluated microhardness, compressive strength, and wear resistance of seven composite resins: six high-filled flowable and one conventional resin. A total of 140 specimens were prepared from seven composite resins (n = 20). The materials tested included Omnichroma Flow (OCF), Vittra Unique Flow (VUF), Estelite Universal Flow High (EUFH), Medium (EUFM), Superlow (EUFS), Genial Injectable (GUIN), and Filtek Z250 (FZ250). Wear resistance was measured on cylindrical specimens (12 mm × 2 mm ) using a reciprocating tribometer with a Al₂O₃ antagonist, 20 N load, 1 mm stroke, 2.5 mm/s speed, and 1500 cycles. Compressive strength was tested on cylindrical specimens (4 mm × 6 mm) with a universal testing machine at 0.5 mm/min crosshead speed. Vickers microhardness was measured on disc specimens (2 mm × 8 mm) with a 100 g load for 10 s. One-way ANOVA and Tukey HSD tests (p < 0.05) were used for statistical analysis. EUFH, VUF, and OCF had significantly higher wear volumes than FZ250. FZ250 had greater microhardness than all high-filled flowable composites. Although the compressive strength values of the tested high-filled flowable composites were similar to that of the conventional composite resin, variations were observed among the flowable composites themselves. Under the conditions of this in vitro study, high-filled flowable composites showed comparable compressive strength to a conventional composite resin but tended to exhibit higher wear and lower surface hardness, which should be considered when selecting materials for stress-bearing restorations.

Scientific ReportsVol. 16(1)
Giresun University (TR)
Sustainable cities and communities
Openalex Percentile: Top 44%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.