Interlaboratory Method Validation for Determination of Polysorbate 80 for Analysis of mAbs

Polysorbate 80 (PS80) is a widely used surfactant in therapeutic monoclonal antibodies (mAbs) because it prevents mAb aggregation and stabilizes the drug product. Various analytical methods have been published and are available for measuring PS80, each with its own limitations. In this study, an HPLC method employing an evaporative light scattering detector (ELSD) was developed for multiproduct analysis of PS80. Method validation was conducted across multiple laboratories using different types of instruments and ELSD detectors. The method was validated using various immunoglobulin G (IgG) mAb molecules and different sources of PS80, with the results showing that it can accurately measure PS80 concentrations ranging from 0.05 to 0.5 mg/mL. Robustness tests demonstrated that the method tolerates up to 160 mg/mL mAb interference, through either sample dilution or protein precipitation. This method can be recommended as a release/quality control method for PS80 concentration determination in therapeutic mAbs.

Authors

Institutions

Publication Details

Journal
Biological and Pharmaceutical Bulletin
Published
2026-02-25
DOI
https://doi.org/10.1248/bpb.b25-00345
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Interlaboratory Method Validation for Determination of Polysorbate 80 for Analysis of mAbs

F. Wang, Chuanfei Yu, Xiaojuan Yu, Lan Wang
Biological and Pharmaceutical Bulletin
Analytical chemistry methods development
article

Interlaboratory Method Validation for Determination of Polysorbate 80 for Analysis of mAbs

F. Wang, Chuanfei Yu, Xiaojuan Yu, Lan Wang
article en

Abstract

Polysorbate 80 (PS80) is a widely used surfactant in therapeutic monoclonal antibodies (mAbs) because it prevents mAb aggregation and stabilizes the drug product. Various analytical methods have been published and are available for measuring PS80, each with its own limitations. In this study, an HPLC method employing an evaporative light scattering detector (ELSD) was developed for multiproduct analysis of PS80. Method validation was conducted across multiple laboratories using different types of instruments and ELSD detectors. The method was validated using various immunoglobulin G (IgG) mAb molecules and different sources of PS80, with the results showing that it can accurately measure PS80 concentrations ranging from 0.05 to 0.5 mg/mL. Robustness tests demonstrated that the method tolerates up to 160 mg/mL mAb interference, through either sample dilution or protein precipitation. This method can be recommended as a release/quality control method for PS80 concentration determination in therapeutic mAbs.

Biological and Pharmaceutical BulletinVol. 49(2)
National Institutes for Food and Drug Control (CN)
Zero hunger
Openalex Percentile: Top 42%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.