Emergent motion capture technology for upper extremity assessment in stroke: A systematic scoping review

ObjectiveTo systematically appraise motion capture technologies used for clinical assessment of upper limb function in adults post stroke, focusing on applicability, strengths, limitations, and research gaps.Data SourcesA systematic scoping review was conducted in accordance with PRISMA-ScR guidelines. PubMed, MEDLINE, CINAHL, CENTRAL, and IEEE Xplore were searched for studies published between January 2014 and December 2025.Review MethodsEligible studies quantitatively evaluated motion capture systems in adult stroke populations. Data extracted included technology type, technical specifications, outcomes, and reported strengths and limitations.ResultsFrom 3217 screened studies, 204 were included. Inertial measurement units were most common (71) followed by markerless optical motion capture (43), electromyography (39), marker-based optical motion capture (33), fusion systems (10), and smart devices (8). Marker-based systems provided high precision but were costly and complex. Markerless systems reduced setup requirements and supported clinical use but were prone to tracking errors. Inertial measurement units enabled portable monitoring, though accuracy decreased for slow or fine movements. Electromyography offered insights into neuromuscular activity but was expensive and sensitive to placement. Fusion systems allowed multidimensional assessment but were resource intensive. Smart devices provided accessible options but lacked precision. Most studies focused on chronic stroke, with limited evaluation in acute or home contexts. Reporting of stroke severity was inconsistent, and protocols were rarely standardised.ConclusionMotion capture technologies show promise for upper limb assessment after stroke but face challenges of cost, accessibility, and standardisation. Research in acute and home settings, along with predictive modelling, is needed to support clinical translation.

Authors

Institutions

Publication Details

Journal
Clinical Rehabilitation
Published
2026-02-25
DOI
https://doi.org/10.1177/02692155261420748
Primary Topic
Stroke Rehabilitation and Recovery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Emergent motion capture technology for upper extremity assessment in stroke: A systematic scoping review

Christine T. Shiner, Alexandra Hurden, CS Anderson, Natasha A. Lannin et al.
Clinical Rehabilitation
Stroke Rehabilitation and Recovery
article

Emergent motion capture technology for upper extremity assessment in stroke: A systematic scoping review

Christine T. Shiner, Alexandra Hurden, CS Anderson, Natasha A. Lannin, Kate Makroglou, Justine Tinker, Xiaoying Chen, Lorraine Li, Jack Weston, Ceyaan Rauniyar, Jarrad Fisher
article en

Abstract

ObjectiveTo systematically appraise motion capture technologies used for clinical assessment of upper limb function in adults post stroke, focusing on applicability, strengths, limitations, and research gaps.Data SourcesA systematic scoping review was conducted in accordance with PRISMA-ScR guidelines. PubMed, MEDLINE, CINAHL, CENTRAL, and IEEE Xplore were searched for studies published between January 2014 and December 2025.Review MethodsEligible studies quantitatively evaluated motion capture systems in adult stroke populations. Data extracted included technology type, technical specifications, outcomes, and reported strengths and limitations.ResultsFrom 3217 screened studies, 204 were included. Inertial measurement units were most common (71) followed by markerless optical motion capture (43), electromyography (39), marker-based optical motion capture (33), fusion systems (10), and smart devices (8). Marker-based systems provided high precision but were costly and complex. Markerless systems reduced setup requirements and supported clinical use but were prone to tracking errors. Inertial measurement units enabled portable monitoring, though accuracy decreased for slow or fine movements. Electromyography offered insights into neuromuscular activity but was expensive and sensitive to placement. Fusion systems allowed multidimensional assessment but were resource intensive. Smart devices provided accessible options but lacked precision. Most studies focused on chronic stroke, with limited evaluation in acute or home contexts. Reporting of stroke severity was inconsistent, and protocols were rarely standardised.ConclusionMotion capture technologies show promise for upper limb assessment after stroke but face challenges of cost, accessibility, and standardisation. Research in acute and home settings, along with predictive modelling, is needed to support clinical translation.

Clinical Rehabilitation
The George Institute for Global Health (GB), Purdue University West Lafayette (US), Fudan University (CN), Royal Prince Alfred Hospital (AU), Liverpool Hospital (AU), Australian Regenerative Medicine Institute (AU), UNSW Sydney (AU), St Vincent's Hospital Sydney (AU), St George Hospital (AU), Alfred Health (AU), Monash University (AU), Australian Catholic University (AU)
Openalex Percentile: Top 43%
Stroke Rehabilitation and Recovery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.