Development of a machine learning model for malaria parasite detection in peripheral blood smears: a preliminary evaluation using Create ML

Background Microscopic examination of peripheral blood smears (PBSs) remains the gold standard for malaria diagnosis but is time-consuming and prone to interobserver variability. Artificial intelligence-based approaches can assist in malaria parasite (MPs) detection; however, many existing models require coding expertise or lack integration into laboratory workflows. The study aims to demonstrate the development and deployment of a code-free machine learning (ML) model for MP detection using a benchtop digital laboratory microscope. Methods In this retrospective study, archived Leishman-stained PBS slides positive for Plasmodium vivax and P. falciparum were digitised at 1000× magnification. 422 fields across 40 slides were digitised, segmented and augmented to yield 7041 images, which were divided into training, validation and test subsets in an 80:10:10 ratio. Ring forms, trophozoites, leucocytes and platelets were annotated in the images. Apple’s Create ML software platform was used for model training. The outcomes were assessed using intersection over union at a 50% threshold (IoU 50 ), F1-score (harmonic mean of precision and recall) and confusion matrix analysis. The trained model was deployed on a digital benchtop laboratory microscope for live object detection overlay. Results The ML model demonstrated a localisation accuracy (IoU 50 ) of 89% and 88% during training and validation, respectively. During testing, a mean IoU 50 of 80% was obtained, ranging from 64% for ring forms to 95% for trophozoites, with a mean precision of 92%, a recall of 93% and an F1 score of 0.93 for object classification. Conclusions This study demonstrates the feasibility of developing an ML model for MP detection using a code-free platform and implementation on a digital laboratory microscope.

Authors

Institutions

Publication Details

Journal
BMJ Innovations
Published
2026-02-25
DOI
https://doi.org/10.1136/bmjinnov-2025-001443
Primary Topic
Digital Imaging for Blood Diseases
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a machine learning model for malaria parasite detection in peripheral blood smears: a preliminary evaluation using Create ML

Kamal Deep Joshi, Anubhav Singh, Shilpi Saxena, Parikshit Sanyal
BMJ Innovations
Digital Imaging for Blood Diseases
article

Development of a machine learning model for malaria parasite detection in peripheral blood smears: a preliminary evaluation using Create ML

Kamal Deep Joshi, Anubhav Singh, Shilpi Saxena, Parikshit Sanyal
article en

Abstract

Background Microscopic examination of peripheral blood smears (PBSs) remains the gold standard for malaria diagnosis but is time-consuming and prone to interobserver variability. Artificial intelligence-based approaches can assist in malaria parasite (MPs) detection; however, many existing models require coding expertise or lack integration into laboratory workflows. The study aims to demonstrate the development and deployment of a code-free machine learning (ML) model for MP detection using a benchtop digital laboratory microscope. Methods In this retrospective study, archived Leishman-stained PBS slides positive for Plasmodium vivax and P. falciparum were digitised at 1000× magnification. 422 fields across 40 slides were digitised, segmented and augmented to yield 7041 images, which were divided into training, validation and test subsets in an 80:10:10 ratio. Ring forms, trophozoites, leucocytes and platelets were annotated in the images. Apple’s Create ML software platform was used for model training. The outcomes were assessed using intersection over union at a 50% threshold (IoU 50 ), F1-score (harmonic mean of precision and recall) and confusion matrix analysis. The trained model was deployed on a digital benchtop laboratory microscope for live object detection overlay. Results The ML model demonstrated a localisation accuracy (IoU 50 ) of 89% and 88% during training and validation, respectively. During testing, a mean IoU 50 of 80% was obtained, ranging from 64% for ring forms to 95% for trophozoites, with a mean precision of 92%, a recall of 93% and an F1 score of 0.93 for object classification. Conclusions This study demonstrates the feasibility of developing an ML model for MP detection using a code-free platform and implementation on a digital laboratory microscope.

BMJ Innovations
Tezpur Medical College & Hospital (IN), Fistulacure (IN), INHS Asvini (IN), Armed Forces Medical College (IN)
Good health and well-being
Openalex Percentile: Top 45%
Digital Imaging for Blood Diseases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.