Machine learning analysis of s-EASIX for predicting 30-day mortality in sepsis patients from MIMIC-IV

Endothelial dysfunction is an important risk factor for the progression of sepsis. The simplified endothelial activation and stress index (s-EASIX) serves as an indirect measure of endothelial activation, whose dynamic changes have an unclear association with prognosis in sepsis. Therefore, we conducted this study to investigate the association between clinical subphenotypes indicated by s-EASIX trajectories and 30-d mortality in sepsis. Based on MIMIC-IV v3.1, the association of s-EASIX dynamic trajectories with 30-d mortality in sepsis was investigated in this retrospective cohort analysis. The prognostic value of trajectory patterns was verified by Kaplan-Meier curves, multivariate regression, and subgroup analyses. Machine learning models incorporating s-EASIX were established, and the weights of contribution of key variables to model decision-making were revealed using SHAP values. This study screened 8113 sepsis patients and identified five classes of s-EASIX trajectories. Cox proportional hazards regression revealed that the 30-d mortality significantly rose in Class 4 (Mid-Increasing) (HR 1.79, 95% CI 1.51-2.11) and Class 5 (High-SlowDecline) (HR 2.53, 95% CI 2.06-3.11), and it was comparable between Class 3 (High-FastDecline) and Class 1/2 (Low-Stable and Mid-Stable). The independent prognostic value of trajectory patterns was verified by multivariate regression, and the HR values for high-risk trajectories remained within 2.53-5.95 after adjusting for demographics and confounders. According to model assessment, LightGBM exhibited superior performance in the validation set (AUC 0.842, 95% CI 0.818-0.866), and its predictive reliability was proven by the Brier score (0.014 in the validation set). Moreover, we analyzed the SHAP values and identified the s-EASIX trajectory as the core variable; the model served as an interpretable tool for risk stratification and early intervention in high-risk sepsis patients. The dynamic increasing pattern of the s-EASIX trajectory correlates with the elevation of 30-d mortality in sepsis, suggesting that persistent endothelial dysfunction raises the risk of unfavorable prognosis.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-02-26
DOI
https://doi.org/10.1038/s41598-026-40400-1
Primary Topic
Sepsis Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Machine learning analysis of s-EASIX for predicting 30-day mortality in sepsis patients from MIMIC-IV

Zhenghui Kong, Qiujiang Liu, Hong Guo, Zhiyu Liu et al.
Scientific Reports
Sepsis Diagnosis and Treatment
article

Machine learning analysis of s-EASIX for predicting 30-day mortality in sepsis patients from MIMIC-IV

Zhenghui Kong, Qiujiang Liu, Hong Guo, Zhiyu Liu, Huilong Chen, Zhiyi Zeng, Yuwei Liu
article en

Abstract

Endothelial dysfunction is an important risk factor for the progression of sepsis. The simplified endothelial activation and stress index (s-EASIX) serves as an indirect measure of endothelial activation, whose dynamic changes have an unclear association with prognosis in sepsis. Therefore, we conducted this study to investigate the association between clinical subphenotypes indicated by s-EASIX trajectories and 30-d mortality in sepsis. Based on MIMIC-IV v3.1, the association of s-EASIX dynamic trajectories with 30-d mortality in sepsis was investigated in this retrospective cohort analysis. The prognostic value of trajectory patterns was verified by Kaplan-Meier curves, multivariate regression, and subgroup analyses. Machine learning models incorporating s-EASIX were established, and the weights of contribution of key variables to model decision-making were revealed using SHAP values. This study screened 8113 sepsis patients and identified five classes of s-EASIX trajectories. Cox proportional hazards regression revealed that the 30-d mortality significantly rose in Class 4 (Mid-Increasing) (HR 1.79, 95% CI 1.51-2.11) and Class 5 (High-SlowDecline) (HR 2.53, 95% CI 2.06-3.11), and it was comparable between Class 3 (High-FastDecline) and Class 1/2 (Low-Stable and Mid-Stable). The independent prognostic value of trajectory patterns was verified by multivariate regression, and the HR values for high-risk trajectories remained within 2.53-5.95 after adjusting for demographics and confounders. According to model assessment, LightGBM exhibited superior performance in the validation set (AUC 0.842, 95% CI 0.818-0.866), and its predictive reliability was proven by the Brier score (0.014 in the validation set). Moreover, we analyzed the SHAP values and identified the s-EASIX trajectory as the core variable; the model served as an interpretable tool for risk stratification and early intervention in high-risk sepsis patients. The dynamic increasing pattern of the s-EASIX trajectory correlates with the elevation of 30-d mortality in sepsis, suggesting that persistent endothelial dysfunction raises the risk of unfavorable prognosis.

Scientific ReportsVol. 16(1)
Guangzhou University of Chinese Medicine (CN), Sun Yat-sen University (CN), Guangdong Provincial Hospital of Traditional Chinese Medicine (CN), Fifth Affiliated Hospital of Sun Yat-sen University (CN), Chengdu University of Traditional Chinese Medicine (CN)
Good health and well-being
Openalex Percentile: Top 43%
Sepsis Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.