Changes in Peri-Implant Soft Tissue Dimensions Following Soft Tissue Contour Augmentation: A 3-Year Follow-Up of a Multi-Center RCT

Aim: To assess 3-year changes of peri-implant tissues following previous soft tissue (volume) augmentation (STA) with a volume-stable collagen matrix (VCMX) or connective tissue (SCTG) at single-implant restorations. Material and methods: In a non-interventional follow-up observation, peri-implant tissues were evaluated with regard to buccal mucosal thickness (MT) and contour, peri-implant conditions: probing depth (PD), bleeding on probing (BOP), plaque (PI), mucosal margin level/crown height (CH), and clinician-reported esthetics (PE and PES). Patient- and clinician-reported satisfaction was recorded at 3 years (VAS). Mixed-effects models were used to compare the groups. Results: Fifty-six patients (age: 48.0 ± 15.5 years) were followed. MT changes over time did not differ between groups [3.9 ± 1.4 mm to 2.6 ± 1.1 mm for VCMX; 3.8 ± 1.3 mm to 2.9 ± 1.2 mm for SCTG]. The estimated intergroup mean difference (VCMX-SCTG) was 0.2 mm (p = 0.587). Mucosal recession was minimal in both groups [0.2 ± 1.0 mm (VCMX) and 0.2 ± 0.6 mm (SCTG)]. At 3 years, intergroup differences in PE scores amounted to 0.5 at mesial (p = 0.06) and distal sites (p = 0.023) in favor of SCTG. PES scores were high in both groups (VCMX = 10.8; SCTG = 10.9) with no significant differences between the groups (p = 0.580). Patient-reported satisfaction with overall esthetics was high (VAS: SCTG = 9.5; VCMX = 9.6) with no significant intergroup differences. Clinician-reported satisfaction was significantly higher for SCTG (VAS: 8.5) compared with VCMX (VAS: 7.4; p = 0.04). Conclusion: Both VCMX and SCTG maintained stable peri-implant soft tissues with minimal contour changes 3 years after implant loading. Clinician-reported outcome-esthetics overall-favored SCTG; however, patient-reported outcomes did not support this finding.

Authors

Publication Details

Journal
Universität Zürich, ZORA
Published
2025-12-13
DOI
https://doi.org/10.5167/uzh-292550
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Changes in Peri-Implant Soft Tissue Dimensions Following Soft Tissue Contour Augmentation: A 3-Year Follow-Up of a Multi-Center RCT

Leonardo Mancini, Karin Jepsen, Christoph H. F. Hämmerle, Stefan Hicklin et al.
Universität Zürich, ZORA
Dental Implant Techniques and Outcomes
article

Changes in Peri-Implant Soft Tissue Dimensions Following Soft Tissue Contour Augmentation: A 3-Year Follow-Up of a Multi-Center RCT

Leonardo Mancini, Karin Jepsen, Christoph H. F. Hämmerle, Stefan Hicklin, Mariano Sanz, Daniel Thoma, Ignacio Sanz Martín, Malin Strasding, Irena Sailer, Søren Jepsen, Franz J. Strauss
article en

Abstract

Aim: To assess 3-year changes of peri-implant tissues following previous soft tissue (volume) augmentation (STA) with a volume-stable collagen matrix (VCMX) or connective tissue (SCTG) at single-implant restorations. Material and methods: In a non-interventional follow-up observation, peri-implant tissues were evaluated with regard to buccal mucosal thickness (MT) and contour, peri-implant conditions: probing depth (PD), bleeding on probing (BOP), plaque (PI), mucosal margin level/crown height (CH), and clinician-reported esthetics (PE and PES). Patient- and clinician-reported satisfaction was recorded at 3 years (VAS). Mixed-effects models were used to compare the groups. Results: Fifty-six patients (age: 48.0 ± 15.5 years) were followed. MT changes over time did not differ between groups [3.9 ± 1.4 mm to 2.6 ± 1.1 mm for VCMX; 3.8 ± 1.3 mm to 2.9 ± 1.2 mm for SCTG]. The estimated intergroup mean difference (VCMX-SCTG) was 0.2 mm (p = 0.587). Mucosal recession was minimal in both groups [0.2 ± 1.0 mm (VCMX) and 0.2 ± 0.6 mm (SCTG)]. At 3 years, intergroup differences in PE scores amounted to 0.5 at mesial (p = 0.06) and distal sites (p = 0.023) in favor of SCTG. PES scores were high in both groups (VCMX = 10.8; SCTG = 10.9) with no significant differences between the groups (p = 0.580). Patient-reported satisfaction with overall esthetics was high (VAS: SCTG = 9.5; VCMX = 9.6) with no significant intergroup differences. Clinician-reported satisfaction was significantly higher for SCTG (VAS: 8.5) compared with VCMX (VAS: 7.4; p = 0.04). Conclusion: Both VCMX and SCTG maintained stable peri-implant soft tissues with minimal contour changes 3 years after implant loading. Clinician-reported outcome-esthetics overall-favored SCTG; however, patient-reported outcomes did not support this finding.

Universität Zürich, ZORA
Life in Land
Openalex Percentile: Top 23%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.