Optimization of seismic performance of high-rise building shear walls based on partial replacement of concrete and steel pipe reinforcement

There are deficiencies in the optimization of the seismic performance of high-rise building shear walls, such as weak integrity and collapse resistance. Aiming at this problem, this study innovatively combines the partial replacement of concrete and steel pipe reinforcement technology, and proposes a method of locally adding steel pipe reinforcement shear walls. The experimental results showed that the specimens reinforced by the studied method exhibited better ductility and toughness when subjected to a vertical load of 840.84 kN as compared to the low-strength concrete specimens that were not reinforced by the studied method. The overall structure of the wall was able to maintain its load-bearing capacity despite the fact that the concrete at its base also suffered from crushing and spalling. In addition, the cracking displacement of the specimens (JGC-2, JGC-4, JGC-6) with localized steel pipe reinforcement was only 3.0 mm, 2.1 mm, 2.4 mm, respectively. The limit displacement was only 27.0 mm, 24.0 mm, 25.0 mm, and 45.0 mm, 47.0 mm, and 36.0 mm, respectively. The destructive displacement was only 45.0 mm, 47.0 mm, and 36.0 mm. The superiority of partial replacement of concrete and steel pipe reinforcement in improving the performance of high-rise building shear wall structures was further confirmed. It can be concluded that the research method can not only provide new ideas for the seismic strengthening of existing high-rise buildings, but also is expected to play an important role in a wider range of engineering applications. In turn, this will contribute to the improvement of the seismic performance of high-rise building structures and the protection of people's lives and property safety.

Authors

Institutions

Publication Details

Journal
Journal of Vibroengineering
Published
2026-02-25
DOI
https://doi.org/10.21595/jve.2025.25290
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of seismic performance of high-rise building shear walls based on partial replacement of concrete and steel pipe reinforcement

Zhengwei Ma
Journal of Vibroengineering
Structural Behavior of Reinforced Concrete
article

Optimization of seismic performance of high-rise building shear walls based on partial replacement of concrete and steel pipe reinforcement

Zhengwei Ma
article en

Abstract

There are deficiencies in the optimization of the seismic performance of high-rise building shear walls, such as weak integrity and collapse resistance. Aiming at this problem, this study innovatively combines the partial replacement of concrete and steel pipe reinforcement technology, and proposes a method of locally adding steel pipe reinforcement shear walls. The experimental results showed that the specimens reinforced by the studied method exhibited better ductility and toughness when subjected to a vertical load of 840.84 kN as compared to the low-strength concrete specimens that were not reinforced by the studied method. The overall structure of the wall was able to maintain its load-bearing capacity despite the fact that the concrete at its base also suffered from crushing and spalling. In addition, the cracking displacement of the specimens (JGC-2, JGC-4, JGC-6) with localized steel pipe reinforcement was only 3.0 mm, 2.1 mm, 2.4 mm, respectively. The limit displacement was only 27.0 mm, 24.0 mm, 25.0 mm, and 45.0 mm, 47.0 mm, and 36.0 mm, respectively. The destructive displacement was only 45.0 mm, 47.0 mm, and 36.0 mm. The superiority of partial replacement of concrete and steel pipe reinforcement in improving the performance of high-rise building shear wall structures was further confirmed. It can be concluded that the research method can not only provide new ideas for the seismic strengthening of existing high-rise buildings, but also is expected to play an important role in a wider range of engineering applications. In turn, this will contribute to the improvement of the seismic performance of high-rise building structures and the protection of people's lives and property safety.

Journal of Vibroengineering
Henan University of Urban Construction (CN)
Sustainable cities and communities
Openalex Percentile: Top 44%
Structural Behavior of Reinforced Concrete
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.