Development and characterization of MPGD-based transition radiation detectors

Transition Radiation Detectors (TRDs) are useful for electron identification and hadron suppression in high energy nuclear and particle physics experiments. Conventional wire-chamber TRDs face operational limitations due to space charge effects, motivating the replacement of the amplification stage with MicroPattern Gaseous Detectors (MPGDs). This work explores different MPGD technologies - Gas Electron Multiplier (GEM), Micro-Mesh Gaseous Structure (Micromegas), and Resistive Micro-Well ( μ RWELL) - as alternative TRD amplification stages. We report on the design, construction, and in-beam characterization of multiple MPGD-based TRD prototypes exposed to 3–20 GeV mixed electron–hadron beams at the Fermilab Test Beam Facility and at the CERN SPS H8 beamline. Each detector consisted of a multi-layered radiator, an approximately 2 cm deep drift region, an MPGD amplification stage optimized for X-ray transition radiation detection in a Xe:CO 2 (90:10) gas mixture, and a two-dimensional readout. The GEM-based TRD prototype achieved a pion suppression factor of about 8 at 90% electron efficiency, while the Micromegas-based prototype - with an added GEM preamplification layer - demonstrated improved operational stability and clear TR photon discrimination. The μ RWELL prototype achieved stable operation but limited signal gain. Geant4 -based studies confirmed the observed trends and highlighted the sensitivity of the TR yield to cathode material and radiator configuration. These studies represent the first in-beam measurements of Micromegas- and μ RWELL-based TRDs, along with discussion of the performance capabilities of a triple-GEM-TRD. The results demonstrate the feasibility of MPGDs as scalable, high-rate amplification structures for next-generation TRD applications.

Authors

Institutions

Publication Details

Journal
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
Published
2026-02-25
DOI
https://doi.org/10.1016/j.nima.2026.171403
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and characterization of MPGD-based transition radiation detectors

S. Furletov, K. Gnanvo, L. Pentchev, S. Tarafdar et al.
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
Particle Detector Development and Performance
article

Development and characterization of MPGD-based transition radiation detectors

S. Furletov, K. Gnanvo, L. Pentchev, S. Tarafdar, A. Austregesilo, Yulia Furletova, Fernando Barbosa, Lauren Kasper, Cody Dickover, Julia Velkovska, Senta Vicki Greene
article en

Abstract

Transition Radiation Detectors (TRDs) are useful for electron identification and hadron suppression in high energy nuclear and particle physics experiments. Conventional wire-chamber TRDs face operational limitations due to space charge effects, motivating the replacement of the amplification stage with MicroPattern Gaseous Detectors (MPGDs). This work explores different MPGD technologies - Gas Electron Multiplier (GEM), Micro-Mesh Gaseous Structure (Micromegas), and Resistive Micro-Well ( μ RWELL) - as alternative TRD amplification stages. We report on the design, construction, and in-beam characterization of multiple MPGD-based TRD prototypes exposed to 3–20 GeV mixed electron–hadron beams at the Fermilab Test Beam Facility and at the CERN SPS H8 beamline. Each detector consisted of a multi-layered radiator, an approximately 2 cm deep drift region, an MPGD amplification stage optimized for X-ray transition radiation detection in a Xe:CO 2 (90:10) gas mixture, and a two-dimensional readout. The GEM-based TRD prototype achieved a pion suppression factor of about 8 at 90% electron efficiency, while the Micromegas-based prototype - with an added GEM preamplification layer - demonstrated improved operational stability and clear TR photon discrimination. The μ RWELL prototype achieved stable operation but limited signal gain. Geant4 -based studies confirmed the observed trends and highlighted the sensitivity of the TR yield to cathode material and radiator configuration. These studies represent the first in-beam measurements of Micromegas- and μ RWELL-based TRDs, along with discussion of the performance capabilities of a triple-GEM-TRD. The results demonstrate the feasibility of MPGDs as scalable, high-rate amplification structures for next-generation TRD applications.

Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated EquipmentVol. 1087
Vanderbilt University (US), Thomas Jefferson National Accelerator Facility (US)
Openalex Percentile: Top 42%
Particle Detector Development and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.