Lung ultrasound predicts surfactant need in neonates on different respiratory support: an international diagnostic accuracy study

An early lung ultrasound score (eaLUS) predicts surfactant administration in neonates of any gestational age with respiratory distress syndrome stabilized on CPAP. Whether this is also true for more unwell infants, non invasively and invasively ventilated, is not known. To assess whether an eaLUS may predict surfactant replacement in infants on different respiratory support modes (CPAP, nasal ventilation and mechanical ventilation). We also investigated eaLUS as a potential marker of unfavorable respiratory outcomes. Prospective, international, multicenter diagnostic study conducted from March 2024 to March 2025 in seven, level III Italian and Spanish neonatal intensive care units. Participants: neonates of any gestational age presenting with respiratory distress, enrolled within 2 h of birth and before the administration of surfactant. Intervention: eaLUS calculated within the first 2 h of life masked to attending physician evaluating both the type of respiratory support and the need for surfactant administration. Main outcome: prognostic accuracy of eaLUS to predict surfactant administration overall and in three subgroups based on early respiratory stabilization strategy (CPAP, NIV and MV). As secondary outcomes we investigated the accuracy of oxygen inspiratory fraction (FiO2) > 0.3 by mode of respiratory support to predict surfactant need. Additionally, logistic regression analysis was used to investigate the link between eaLUS with prolonged mechanical ventilation and death or BPD as secondary outcomes. We enrolled 229 infants stabilized on CPAP (n = 117), nasal ventilation (n = 58) and mechanical ventilation (n = 54). eaLUS had good prognostic accuracy in the total population (AUC, 0.86; 95% CI, 0.81–0.91). Despite the wide gap of mean airway pressure (MAP) across the population, eaLUS and MAP were only moderately correlated (rho = 0.39; p < 0.001). Optimal thresholds for surfactant replacement were slightly different (LUS ≥ 8 for CPAP; LUS ≥ 9 for nasal ventilation; LUS ≥ 10 for mechanical ventilation). FiO2 > 0.3 was a less accurate predictor of surfactant replacement. eaLUS was significantly associated to prolonged mechanical ventilation beyond both 72 and 168 h. Finally, eaLUS emerged as an independent predictor of BPD or death. An early LUS accurately predicts surfactant replacement in neonates non invasively and invasively ventilated and it is a noninvasive imaging prognostic marker of disease severity and adverse respiratory outcomes in this population. ISRCTN Registry (number ISRCTN10205806).

Authors

Institutions

Publication Details

Journal
Respiratory Research
Published
2026-02-26
DOI
https://doi.org/10.1186/s12931-026-03585-7
Primary Topic
Ultrasound in Clinical Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Lung ultrasound predicts surfactant need in neonates on different respiratory support: an international diagnostic accuracy study

Gianluca Lista, Fiorella Migliaro, Chiara Colinet, Stefano Nobile et al.
Respiratory Research
Ultrasound in Clinical Applications
article

Lung ultrasound predicts surfactant need in neonates on different respiratory support: an international diagnostic accuracy study

Gianluca Lista, Fiorella Migliaro, Chiara Colinet, Stefano Nobile, Javier Rodríguez Fanjul, Luca Bonadies, Almudena Alonso Ojembarrena, Pasquale Dolce, Francesco Raimondi, Mario Meliande, Rebeca Gregorio Hernandez, Fabio Meneghin, Marco Fossati, Giovanni Vento, Stefano Martinelli, Manuel Sanchez Luna, Irene Gutierrez Rosa, Eugenio Baraldi, Peter G. Davis
article en

Abstract

An early lung ultrasound score (eaLUS) predicts surfactant administration in neonates of any gestational age with respiratory distress syndrome stabilized on CPAP. Whether this is also true for more unwell infants, non invasively and invasively ventilated, is not known. To assess whether an eaLUS may predict surfactant replacement in infants on different respiratory support modes (CPAP, nasal ventilation and mechanical ventilation). We also investigated eaLUS as a potential marker of unfavorable respiratory outcomes. Prospective, international, multicenter diagnostic study conducted from March 2024 to March 2025 in seven, level III Italian and Spanish neonatal intensive care units. Participants: neonates of any gestational age presenting with respiratory distress, enrolled within 2 h of birth and before the administration of surfactant. Intervention: eaLUS calculated within the first 2 h of life masked to attending physician evaluating both the type of respiratory support and the need for surfactant administration. Main outcome: prognostic accuracy of eaLUS to predict surfactant administration overall and in three subgroups based on early respiratory stabilization strategy (CPAP, NIV and MV). As secondary outcomes we investigated the accuracy of oxygen inspiratory fraction (FiO2) > 0.3 by mode of respiratory support to predict surfactant need. Additionally, logistic regression analysis was used to investigate the link between eaLUS with prolonged mechanical ventilation and death or BPD as secondary outcomes. We enrolled 229 infants stabilized on CPAP (n = 117), nasal ventilation (n = 58) and mechanical ventilation (n = 54). eaLUS had good prognostic accuracy in the total population (AUC, 0.86; 95% CI, 0.81–0.91). Despite the wide gap of mean airway pressure (MAP) across the population, eaLUS and MAP were only moderately correlated (rho = 0.39; p < 0.001). Optimal thresholds for surfactant replacement were slightly different (LUS ≥ 8 for CPAP; LUS ≥ 9 for nasal ventilation; LUS ≥ 10 for mechanical ventilation). FiO2 > 0.3 was a less accurate predictor of surfactant replacement. eaLUS was significantly associated to prolonged mechanical ventilation beyond both 72 and 168 h. Finally, eaLUS emerged as an independent predictor of BPD or death. An early LUS accurately predicts surfactant replacement in neonates non invasively and invasively ventilated and it is a noninvasive imaging prognostic marker of disease severity and adverse respiratory outcomes in this population. ISRCTN Registry (number ISRCTN10205806).

Respiratory ResearchVol. 27(1)
Università Cattolica del Sacro Cuore (IT), Universidad Complutense de Madrid (ES), Royal Women's Hospital (AU), University of Padua (IT), The University of Melbourne (AU), Hospital General Universitario Gregorio Marañón (ES), Azienda Socio Sanitaria Territoriale Grande Ospedale Metropolitano Niguarda (IT), Federico II University Hospital (IT), Ospedale dei Bambini Vittore Buzzi (IT), Hospital Universitario Puerta del Mar (ES), Hospital Universitari Germans Trias i Pujol (ES), University of Naples Federico II (IT)
Openalex Percentile: Top 45%
Ultrasound in Clinical Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.