A water-first hybrid renewable energy system with gravity-based storage for remote settlements

This study proposes a water-first hybrid renewable energy system that integrates solar photovoltaic (PV) and wind generation with gravity-based water storage, treating stored water primarily as household infrastructure while enabling opportunistic electrical energy recovery. During periods of surplus renewable production, excess power drives a DC pump that lifts water from a groundwater source into an elevated storage tank; a three-way diverter valve then directs discharge either for direct household use or through a micro-hydropower turbine to bridge renewable shortfalls. A rule-based controller activates pumping only under renewable surplus and enables turbine-assisted discharge only during renewable deficits when sufficient tank volume is available and battery state of charge is constrained. A time-domain simulation (1 s timestep, 24 h horizon) was evaluated for a representative household case (PV peak 2 kW, mean wind 0.5 kW, electrical load ≈18 kWh/day, water demand 1.2 m³/day) using a 30 m³ tank at 60 m effective head and micro-hydropower generation in the 100–500 W range. In the representative case, hybrid operation recovers 2.83 kWh/day of electrical energy from 5.75 kWh/day of pumping input (recovery fraction ≈49%) and reduces unmet household electrical demand from 5.04 kWh/day to 2.21 kWh/day relative to a direct-use baseline. Daily battery discharge remains modest (~0.36 kWh/day). Monte Carlo analysis over 500 trials with randomized renewable generation, electrical load, and water-use timing (design fixed) demonstrates robust performance, with a mean recovered energy of 2.63 kWh/day (95% CI: 2.60–2.66). These results clarify realistic energy scales for micro-scale gravity storage and position the system as a co-designed water infrastructure with secondary, reliability-oriented electrical energy recovery rather than as a primary electrical storage solution. This work provides one of the first quantitative, stochastic evaluations of household-scale gravity storage co-designed with domestic water infrastructure, establishing realistic upper bounds on recoverable energy and reliability impacts.

Authors

Institutions

Publication Details

Journal
Journal of High School Science
Published
2026-02-25
DOI
https://doi.org/10.64336/001c.158347
Primary Topic
Hybrid Renewable Energy Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A water-first hybrid renewable energy system with gravity-based storage for remote settlements

Yerbolat Sailaukhanuly, Kirill Ostrovskiy
Journal of High School Science
Hybrid Renewable Energy Systems
article

A water-first hybrid renewable energy system with gravity-based storage for remote settlements

Yerbolat Sailaukhanuly, Kirill Ostrovskiy
article en

Abstract

This study proposes a water-first hybrid renewable energy system that integrates solar photovoltaic (PV) and wind generation with gravity-based water storage, treating stored water primarily as household infrastructure while enabling opportunistic electrical energy recovery. During periods of surplus renewable production, excess power drives a DC pump that lifts water from a groundwater source into an elevated storage tank; a three-way diverter valve then directs discharge either for direct household use or through a micro-hydropower turbine to bridge renewable shortfalls. A rule-based controller activates pumping only under renewable surplus and enables turbine-assisted discharge only during renewable deficits when sufficient tank volume is available and battery state of charge is constrained. A time-domain simulation (1 s timestep, 24 h horizon) was evaluated for a representative household case (PV peak 2 kW, mean wind 0.5 kW, electrical load ≈18 kWh/day, water demand 1.2 m³/day) using a 30 m³ tank at 60 m effective head and micro-hydropower generation in the 100–500 W range. In the representative case, hybrid operation recovers 2.83 kWh/day of electrical energy from 5.75 kWh/day of pumping input (recovery fraction ≈49%) and reduces unmet household electrical demand from 5.04 kWh/day to 2.21 kWh/day relative to a direct-use baseline. Daily battery discharge remains modest (~0.36 kWh/day). Monte Carlo analysis over 500 trials with randomized renewable generation, electrical load, and water-use timing (design fixed) demonstrates robust performance, with a mean recovered energy of 2.63 kWh/day (95% CI: 2.60–2.66). These results clarify realistic energy scales for micro-scale gravity storage and position the system as a co-designed water infrastructure with secondary, reliability-oriented electrical energy recovery rather than as a primary electrical storage solution. This work provides one of the first quantitative, stochastic evaluations of household-scale gravity storage co-designed with domestic water infrastructure, establishing realistic upper bounds on recoverable energy and reliability impacts.

Journal of High School ScienceVol. 10(1)
M.Auezov South Kazakhstan State University (KZ)
Industry, innovation and infrastructure
Openalex Percentile: Top 47%
Hybrid Renewable Energy Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.