Organ and Effective Dose Assessments using MCNP with Computational PIMAL Phantoms and Realistic Eye Model in Radiological Workplaces

The female and male computational phantom with moving arms and legs (PIMAL) are useful models for the calculation of the effective doses to workers in radiological occupational settings. In this study, Monte Carlo N-Particle (MCNP) Version 6.2 is used with PIMAL phantoms to simulate exposure in nuclear and medical settings. The PIMAL phantoms, defined by mathematical representation of the human body, allow for detailed assessment of equivalent dose to organs. These values are converted to effective dose (E) using sex- and age-average tissue weighting factors from ICRP Publication 103. Initial simulations of monoenergetic photons, electrons, and neutrons in the anterior-posterior (AP) geometry show good agreement with comparable results in the literature, obtained using the ICRP adult reference voxel phantoms and PIMAL phantoms in the standard upright position. For nuclear power applications, effective dose rates () are estimated for workers contaminated by radionuclides and compared with personal dose equivalent rates at 0.07 mm depth, (0.07). Additionally, effective dose rates from neutron and gamma fields are calculated for personnel inside a CANDU-600 (CANada Deuterium Uranium) nuclear reactor at full-power. In medical applications, effective dose rates to staff exposed to positron emitters, either from injected patients or activated cyclotron targets, are also assessed. Across all scenarios, effective dose derived from PIMAL phantoms are consistent with operational dose quantities when available, supporting their use in dose assessment and radiation protection planning.

Authors

Institutions

Publication Details

Journal
Health Physics
Published
2026-02-25
DOI
https://doi.org/10.1097/hp.0000000000002124
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Organ and Effective Dose Assessments using MCNP with Computational PIMAL Phantoms and Realistic Eye Model in Radiological Workplaces

S. Djeffal, Fawaz Ali, J. Dubeau, A. Talebitaher et al.
Health Physics
Radiation Dose and Imaging
article

Organ and Effective Dose Assessments using MCNP with Computational PIMAL Phantoms and Realistic Eye Model in Radiological Workplaces

S. Djeffal, Fawaz Ali, J. Dubeau, A. Talebitaher, Jiansheng Sun
article en

Abstract

The female and male computational phantom with moving arms and legs (PIMAL) are useful models for the calculation of the effective doses to workers in radiological occupational settings. In this study, Monte Carlo N-Particle (MCNP) Version 6.2 is used with PIMAL phantoms to simulate exposure in nuclear and medical settings. The PIMAL phantoms, defined by mathematical representation of the human body, allow for detailed assessment of equivalent dose to organs. These values are converted to effective dose (E) using sex- and age-average tissue weighting factors from ICRP Publication 103. Initial simulations of monoenergetic photons, electrons, and neutrons in the anterior-posterior (AP) geometry show good agreement with comparable results in the literature, obtained using the ICRP adult reference voxel phantoms and PIMAL phantoms in the standard upright position. For nuclear power applications, effective dose rates () are estimated for workers contaminated by radionuclides and compared with personal dose equivalent rates at 0.07 mm depth, (0.07). Additionally, effective dose rates from neutron and gamma fields are calculated for personnel inside a CANDU-600 (CANada Deuterium Uranium) nuclear reactor at full-power. In medical applications, effective dose rates to staff exposed to positron emitters, either from injected patients or activated cyclotron targets, are also assessed. Across all scenarios, effective dose derived from PIMAL phantoms are consistent with operational dose quantities when available, supporting their use in dose assessment and radiation protection planning.

Health Physics
Canadian Nuclear Safety Commission (CA), Canadian Nuclear Laboratories (CA)
Openalex Percentile: Top 44%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.