Detection of Gaseous Mercuric Halides Using Acetate and Iodide Chemical Ionization Mass Spectrometry

Predicting the fate of gaseous oxidized mercury (GOM) in the atmosphere remains a challenge because no direct analytical methods exist to determine its molecular speciation. Conventional preconcentration techniques produce speciation losses and induce ligand exchange, obscuring the original composition of GOM. Direct analysis by chemical ionization mass spectrometry (CIMS) offers a path toward addressing this analytical challenge, but its success depends critically on the use of an appropriate ion-molecule chemistry. Previously, we showed the applicability of the negative-ion CIMS for detection of gaseous HgCl<sub>2</sub>. Here, we demonstrate the first systematic evaluation of the detection of gaseous mercuric halides (HgCl<sub>2</sub>, HgBr<sub>2</sub>, and HgI<sub>2</sub>) by acetate (CH<sub>3</sub>COO<sup>-</sup>·CH<sub>3</sub>COOH) and iodide (I<sup>-</sup>) reagent ions, which have been successfully used in the past for the detection of atmospheric trace chemicals. As soft Lewis bases, these reagent ions react promptly with mercuric halides through either complexation or ligand switching. Using a calibrated permeation source, we establish the sensitivity and limit of detection (LOD) for HgBr<sub>2</sub> with these and previously reported reagent ions. Measured sensitivities range from 3.8 to 21.0 cps/ppbv (for 1 Mcps reagent ion signal), and in the case of ligand switching, they agree with theoretical sensitivities. The current LOD of 53-268 pptv, obtained at a 2.5 Torr ion-molecule reaction pressure, is sufficient for laboratory studies of Hg chemistry and speciating GOM from combustion flue gases. Operating at higher ion-molecule reaction pressures will significantly enhance ionization efficiency, extending the applicability of CIMS toward direct detection of GOM in the atmosphere.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2026-02-25
DOI
https://doi.org/10.1021/acs.analchem.5c07120
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detection of Gaseous Mercuric Halides Using Acetate and Iodide Chemical Ionization Mass Spectrometry

Alexei F. Khalizov, Mohammad Borna Bahramsari
Analytical Chemistry
Mass Spectrometry Techniques and Applications
article

Detection of Gaseous Mercuric Halides Using Acetate and Iodide Chemical Ionization Mass Spectrometry

Alexei F. Khalizov, Mohammad Borna Bahramsari
article en

Abstract

Predicting the fate of gaseous oxidized mercury (GOM) in the atmosphere remains a challenge because no direct analytical methods exist to determine its molecular speciation. Conventional preconcentration techniques produce speciation losses and induce ligand exchange, obscuring the original composition of GOM. Direct analysis by chemical ionization mass spectrometry (CIMS) offers a path toward addressing this analytical challenge, but its success depends critically on the use of an appropriate ion-molecule chemistry. Previously, we showed the applicability of the negative-ion CIMS for detection of gaseous HgCl<sub>2</sub>. Here, we demonstrate the first systematic evaluation of the detection of gaseous mercuric halides (HgCl<sub>2</sub>, HgBr<sub>2</sub>, and HgI<sub>2</sub>) by acetate (CH<sub>3</sub>COO<sup>-</sup>·CH<sub>3</sub>COOH) and iodide (I<sup>-</sup>) reagent ions, which have been successfully used in the past for the detection of atmospheric trace chemicals. As soft Lewis bases, these reagent ions react promptly with mercuric halides through either complexation or ligand switching. Using a calibrated permeation source, we establish the sensitivity and limit of detection (LOD) for HgBr<sub>2</sub> with these and previously reported reagent ions. Measured sensitivities range from 3.8 to 21.0 cps/ppbv (for 1 Mcps reagent ion signal), and in the case of ligand switching, they agree with theoretical sensitivities. The current LOD of 53-268 pptv, obtained at a 2.5 Torr ion-molecule reaction pressure, is sufficient for laboratory studies of Hg chemistry and speciating GOM from combustion flue gases. Operating at higher ion-molecule reaction pressures will significantly enhance ionization efficiency, extending the applicability of CIMS toward direct detection of GOM in the atmosphere.

Analytical Chemistry
New Jersey Institute of Technology (US)
Openalex Percentile: Top 45%
Mass Spectrometry Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.