Modulated Arc Therapy (mARC) versus intensity-modulated radiation therapy in craniospinal irradiation: Evaluation of CT-slice-defined field junction thickness on dosimetric quality

One of the main technical challenges in craniospinal irradiation (CSI) is the risk of overdosing or underdosing in field overlap regions due to the need to match multiple treatment fields along the Planning Target Volume (PTV). To the authors’ knowledge, the technical and dosimetric feasibility of modulated arc therapy (mARC) has not yet been evaluated for CSI. Unlike other arc techniques, mARC delivers dose in discrete arcs. This study compared mARC with intensity-modulated radiation therapy (IMRT) and analyzed the impact of overlap region thickness, defined by the number of computed tomography (CT) slices, on plan quality. Treatment plans were generated for 10 patients using both mARC and IMRT on a Siemens Artiste linear accelerator. Optimization pseudo-structures were created with 4, 5, 6, and 7 tomographic slices at the craniothoracic and thoracolumbar junctions, resulting in eight plans per patient. The prescribed dose was 36 Gy in 20 fractions. Plans were evaluated by assessing PTV dosimetric parameters, doses to organs at risk (OARs), monitor units (MU), and treatment time. Statistical analysis employed two-way repeated-measures analysis of variance (ANOVA). The treatment technique was the main determinant of dosimetric outcomes. IMRT yielded lower mean dose values to certain OARs (kidneys, heart, lungs, and liver) and higher values for several PTV dose metrics. In contrast, mARC required fewer MUs and shorter treatment times and showed superior conformity and homogeneity indices. The number of CT slices did not produce statistically significant differences, and no significant technique–slice interactions were observed. In CSI, the planning technique has a greater impact on dosimetric outcomes than the thickness of the overlapping field region. mARC improves efficiency in treatment time and MUs and provides improved conformity and homogeneity compared to IMRT. The number of tomographic slices has no impact on dosimetric quality.

Authors

Institutions

Publication Details

Journal
Journal of Radiation Research and Applied Sciences
Published
2026-02-25
DOI
https://doi.org/10.1016/j.jrras.2026.102252
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Modulated Arc Therapy (mARC) versus intensity-modulated radiation therapy in craniospinal irradiation: Evaluation of CT-slice-defined field junction thickness on dosimetric quality

L. E. Cocom-Poot, A. H. Badillo-Alvarado, E.M. Hernández-Neri, E.A. Martín-Tovar
Journal of Radiation Research and Applied Sciences
Advanced Radiotherapy Techniques
article

Modulated Arc Therapy (mARC) versus intensity-modulated radiation therapy in craniospinal irradiation: Evaluation of CT-slice-defined field junction thickness on dosimetric quality

L. E. Cocom-Poot, A. H. Badillo-Alvarado, E.M. Hernández-Neri, E.A. Martín-Tovar
article en

Abstract

One of the main technical challenges in craniospinal irradiation (CSI) is the risk of overdosing or underdosing in field overlap regions due to the need to match multiple treatment fields along the Planning Target Volume (PTV). To the authors’ knowledge, the technical and dosimetric feasibility of modulated arc therapy (mARC) has not yet been evaluated for CSI. Unlike other arc techniques, mARC delivers dose in discrete arcs. This study compared mARC with intensity-modulated radiation therapy (IMRT) and analyzed the impact of overlap region thickness, defined by the number of computed tomography (CT) slices, on plan quality. Treatment plans were generated for 10 patients using both mARC and IMRT on a Siemens Artiste linear accelerator. Optimization pseudo-structures were created with 4, 5, 6, and 7 tomographic slices at the craniothoracic and thoracolumbar junctions, resulting in eight plans per patient. The prescribed dose was 36 Gy in 20 fractions. Plans were evaluated by assessing PTV dosimetric parameters, doses to organs at risk (OARs), monitor units (MU), and treatment time. Statistical analysis employed two-way repeated-measures analysis of variance (ANOVA). The treatment technique was the main determinant of dosimetric outcomes. IMRT yielded lower mean dose values to certain OARs (kidneys, heart, lungs, and liver) and higher values for several PTV dose metrics. In contrast, mARC required fewer MUs and shorter treatment times and showed superior conformity and homogeneity indices. The number of CT slices did not produce statistically significant differences, and no significant technique–slice interactions were observed. In CSI, the planning technique has a greater impact on dosimetric outcomes than the thickness of the overlapping field region. mARC improves efficiency in treatment time and MUs and provides improved conformity and homogeneity compared to IMRT. The number of tomographic slices has no impact on dosimetric quality.

Journal of Radiation Research and Applied SciencesVol. 19(1)
Mexican Social Security Institute (MX), Hospital de Especialidades (MX)
Openalex Percentile: Top 39%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.