Millimeter-wave technology for multi-person fall detection validated through wearable sensors and real-life scenarios

Older adults face increased health risks, especially accidental injuries such as falls, which are one of the top ten causes of death in this age group. To address these changes, recent innovations have focused on developing advanced monitoring technologies to detect and prevent accidents in real time. Among these, fall detection systems have emerged as a critical area of research. This study aimed to evaluate the ability of millimeter-wave (mmWave) sensors to accurately detect multiple falls in the presence of large obstacles in a large, real-world indoor space. The mmWave sensors employed the Doppler effect to capture a human body’s point cloud and track its center point to estimate body position and identify fall events. A 12 $$\times$$ 12 meter indoor test area was established for the trials. The mmWave system’s accuracy was validated with video ground truth. Multiple sensors and azimuth tests were conducted to optimize radar configurations. 10 participants performed multiple human fall detection trials under 10 different scenarios. We have successfully validated the mmWave system with the video ground truth. In fall detection testing, the mmWave system achieved an overall accuracy of 97.9% across 10 multi-person scenarios. The results show that the system’s fall detection false negative rate increases with the number of subjects. This study validated the performance of a mmWave system for fall detection in a large indoor environment, demonstrating a high accuracy of 97.9% in a multi-person scenario. However, performance varied with crowd density, showing a correlation between increased false negative rates and the number of subjects due to occlusion. This study supports that mmWave technology offers good capabilities for fall accident monitoring in large indoor spaces with both privacy protection and convenience. IRB Registry: Institutional Review Board of the Chang Gung Medical Foundation, Approval No.: 202500191B0, Registration date: 3 March 2025.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-02-25
DOI
https://doi.org/10.1038/s41598-026-40330-y
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Millimeter-wave technology for multi-person fall detection validated through wearable sensors and real-life scenarios

Shu-Hsuan Lin, Chieh-Wei Wu, Hsin-Chang Chen, Hsiang-Ho Chen et al.
Scientific Reports
Non-Invasive Vital Sign Monitoring
article

Millimeter-wave technology for multi-person fall detection validated through wearable sensors and real-life scenarios

Shu-Hsuan Lin, Chieh-Wei Wu, Hsin-Chang Chen, Hsiang-Ho Chen, Jui-Da Lin
article en

Abstract

Older adults face increased health risks, especially accidental injuries such as falls, which are one of the top ten causes of death in this age group. To address these changes, recent innovations have focused on developing advanced monitoring technologies to detect and prevent accidents in real time. Among these, fall detection systems have emerged as a critical area of research. This study aimed to evaluate the ability of millimeter-wave (mmWave) sensors to accurately detect multiple falls in the presence of large obstacles in a large, real-world indoor space. The mmWave sensors employed the Doppler effect to capture a human body’s point cloud and track its center point to estimate body position and identify fall events. A 12 $$\times$$ 12 meter indoor test area was established for the trials. The mmWave system’s accuracy was validated with video ground truth. Multiple sensors and azimuth tests were conducted to optimize radar configurations. 10 participants performed multiple human fall detection trials under 10 different scenarios. We have successfully validated the mmWave system with the video ground truth. In fall detection testing, the mmWave system achieved an overall accuracy of 97.9% across 10 multi-person scenarios. The results show that the system’s fall detection false negative rate increases with the number of subjects. This study validated the performance of a mmWave system for fall detection in a large indoor environment, demonstrating a high accuracy of 97.9% in a multi-person scenario. However, performance varied with crowd density, showing a correlation between increased false negative rates and the number of subjects due to occlusion. This study supports that mmWave technology offers good capabilities for fall accident monitoring in large indoor spaces with both privacy protection and convenience. IRB Registry: Institutional Review Board of the Chang Gung Medical Foundation, Approval No.: 202500191B0, Registration date: 3 March 2025.

Scientific ReportsVol. 16(1)
Chang Gung University of Science and Technology (TW), National Yang Ming Chiao Tung University (TW), Chang Gung University (TW), University of Taipei (TW), Chang Gung Memorial Hospital (TW), Linkou Chang Gung Memorial Hospital (TW), Taipei City Hospital (TW)
National Science and Technology Council
Climate action
Openalex Percentile: Top 45%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.