Deep Learning (nnU-Net)-Based Segmentation of Primary HPV-Positive OPSCC: Contrast-Enhanced T1-Weighted Fat-Suppressed Versus Non-Contrast-Enhanced T2-Weighted Fat-Suppressed MRI (Paired Single-Center Study)

<b>Background/Objectives:</b> While deep learning-based AI algorithms have been shown to perform well for OPSCC tumor segmentation, the relative value of contrast-enhanced versus T2-weighted sequences for automated segmentation has not been systematically evaluated. In this study, we compared the sequence-specific deep learning performance on contrast-enhanced T1-weighted fat-suppressed and T2-weighted fat-suppressed MRI in HPV-positive OPSCC. <b>Methods:</b> Pretreatment MRI from 39 patients with paired sequences from a single center were retrospectively analyzed. OPSCC primary tumors were manually segmented using both sequences, which served as the ground truth. Three sequence-specific configurations were evaluated: contrast-enhanced (CE), T2-only, and combined CE + T2. Quantitative evaluation was carried out on aggregated out-of-fold predictions using Dice score (primary), Surface-Dice@2mm (secondary), and other boundary and volumetric metrics, and paired comparisons (combined vs. T2-only; CE-only vs. T2-only) were performed using an exact Wilcoxon signed-rank test. Qualitative evaluation was performed on 4-point ordinal acceptability ratings recorded using a blind reader study, and the ratings were compared using the exact Wilcoxon signed-rank test (pairwise) and dichotomized acceptability using the McNemar test. <b>Results:</b> Median Dice was comparable across configurations (0.63 for CE + T2, 0.60 for T2-only, and 0.55 for CE-only). Median Surface-Dice@2mm was highest for the combined configuration (0.62), followed by CE-only (0.6) and T2-only (0.57). Median ASSD were 2.71, 2.98, and 2.98 mm, and median HD95 were 11.39, 15.0, and 11.3 mm for combined, CE, and T2, respectively. The median GTV differences (-1.31, -1.29, and -1.49 mL for combined, T2, and CE, respectively) showed a slight bias toward under-segmentation across all configurations. No significant differences in Dice scores were observed for combined vs. T2 (<i>p</i> = 0.11) or contrast-enhanced vs. T2-only (<i>p</i> = 0.98). Similarly, qualitative analysis also showed no evidence of performance difference for ratings and acceptability rates across sequence configurations (paired Wilcoxon, <i>p</i> ≥ 0.35; McNemar, <i>p</i> = 1.00). <b>Conclusions:</b> In this single-center study, the segmentation performance using non-contrast sequences was comparable to that using both contrast-enhanced and non-contrast sequences. The drop in performance when the contrast-enhanced sequences were excluded from the combination was not significant. These findings justify multi-center validation to support the feasibility of contrast-sparing automated primary OPSCC segmentation when use of contrast agents is contraindicated.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-02-25
DOI
https://doi.org/10.3390/diagnostics16050658
Primary Topic
Radiomics and Machine Learning in Medical Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Deep Learning (nnU-Net)-Based Segmentation of Primary HPV-Positive OPSCC: Contrast-Enhanced T1-Weighted Fat-Suppressed Versus Non-Contrast-Enhanced T2-Weighted Fat-Suppressed MRI (Paired Single-Center Study)

Ramkumar Rajabathar Babu Jai Shanker, Viktoriia Zarovniaeva, Amogh Shetty, Daniel T. Ginat
Diagnostics
Radiomics and Machine Learning in Medical Imaging
article

Deep Learning (nnU-Net)-Based Segmentation of Primary HPV-Positive OPSCC: Contrast-Enhanced T1-Weighted Fat-Suppressed Versus Non-Contrast-Enhanced T2-Weighted Fat-Suppressed MRI (Paired Single-Center Study)

Ramkumar Rajabathar Babu Jai Shanker, Viktoriia Zarovniaeva, Amogh Shetty, Daniel T. Ginat
article en

Abstract

<b>Background/Objectives:</b> While deep learning-based AI algorithms have been shown to perform well for OPSCC tumor segmentation, the relative value of contrast-enhanced versus T2-weighted sequences for automated segmentation has not been systematically evaluated. In this study, we compared the sequence-specific deep learning performance on contrast-enhanced T1-weighted fat-suppressed and T2-weighted fat-suppressed MRI in HPV-positive OPSCC. <b>Methods:</b> Pretreatment MRI from 39 patients with paired sequences from a single center were retrospectively analyzed. OPSCC primary tumors were manually segmented using both sequences, which served as the ground truth. Three sequence-specific configurations were evaluated: contrast-enhanced (CE), T2-only, and combined CE + T2. Quantitative evaluation was carried out on aggregated out-of-fold predictions using Dice score (primary), Surface-Dice@2mm (secondary), and other boundary and volumetric metrics, and paired comparisons (combined vs. T2-only; CE-only vs. T2-only) were performed using an exact Wilcoxon signed-rank test. Qualitative evaluation was performed on 4-point ordinal acceptability ratings recorded using a blind reader study, and the ratings were compared using the exact Wilcoxon signed-rank test (pairwise) and dichotomized acceptability using the McNemar test. <b>Results:</b> Median Dice was comparable across configurations (0.63 for CE + T2, 0.60 for T2-only, and 0.55 for CE-only). Median Surface-Dice@2mm was highest for the combined configuration (0.62), followed by CE-only (0.6) and T2-only (0.57). Median ASSD were 2.71, 2.98, and 2.98 mm, and median HD95 were 11.39, 15.0, and 11.3 mm for combined, CE, and T2, respectively. The median GTV differences (-1.31, -1.29, and -1.49 mL for combined, T2, and CE, respectively) showed a slight bias toward under-segmentation across all configurations. No significant differences in Dice scores were observed for combined vs. T2 (<i>p</i> = 0.11) or contrast-enhanced vs. T2-only (<i>p</i> = 0.98). Similarly, qualitative analysis also showed no evidence of performance difference for ratings and acceptability rates across sequence configurations (paired Wilcoxon, <i>p</i> ≥ 0.35; McNemar, <i>p</i> = 1.00). <b>Conclusions:</b> In this single-center study, the segmentation performance using non-contrast sequences was comparable to that using both contrast-enhanced and non-contrast sequences. The drop in performance when the contrast-enhanced sequences were excluded from the combination was not significant. These findings justify multi-center validation to support the feasibility of contrast-sparing automated primary OPSCC segmentation when use of contrast agents is contraindicated.

DiagnosticsVol. 16(5)
Rensselaer Polytechnic Institute (US), University of Chicago (US), ILC Dover (United States) (US)
Quality Education
Openalex Percentile: Top 45%
Radiomics and Machine Learning in Medical Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.