Performance Evaluation of AlphaSensor Radon Modules Under Real-World Conditions

This study compares a set of 43 AlphaSensor units produced by RadonTec GmbH, Wittislingen, Germany against the AlphaGUARD 1000PF (Bertin Technologies, Montigny-le-Bretonneux, France), which is used as a reference monitor. During this study, around 16 k integrated measurements were conducted. The concentration range varied between 10 and 20 k Bq/m<sup>3</sup>. Multiple key performance indicators, such as sensitivity, uncertainty, background, linearity, and temporal response, were evaluated using a variety of statistical approaches. The results confirm the manufacturer's claim of 10% or lower uncertainty in comparison with AlphaGUARD. We tentatively suggest individual calibration factors and methodologies. Our conclusion is that the AlphaSensor and commercial devices based on it, such as AlphaTracer, are affordable and applicable for home use. With modest additional hardware, AlphaSensors are also a good option for scientific studies involving the deployment of large monitoring networks.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-02-25
DOI
https://doi.org/10.3390/s26051432
Primary Topic
Radioactivity and Radon Measurements
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Evaluation of AlphaSensor Radon Modules Under Real-World Conditions

Stoyan Tenev, L. Tsankov, Atanas Terziyski
Sensors
Radioactivity and Radon Measurements
article

Performance Evaluation of AlphaSensor Radon Modules Under Real-World Conditions

Stoyan Tenev, L. Tsankov, Atanas Terziyski
article en

Abstract

This study compares a set of 43 AlphaSensor units produced by RadonTec GmbH, Wittislingen, Germany against the AlphaGUARD 1000PF (Bertin Technologies, Montigny-le-Bretonneux, France), which is used as a reference monitor. During this study, around 16 k integrated measurements were conducted. The concentration range varied between 10 and 20 k Bq/m<sup>3</sup>. Multiple key performance indicators, such as sensitivity, uncertainty, background, linearity, and temporal response, were evaluated using a variety of statistical approaches. The results confirm the manufacturer's claim of 10% or lower uncertainty in comparison with AlphaGUARD. We tentatively suggest individual calibration factors and methodologies. Our conclusion is that the AlphaSensor and commercial devices based on it, such as AlphaTracer, are affordable and applicable for home use. With modest additional hardware, AlphaSensors are also a good option for scientific studies involving the deployment of large monitoring networks.

SensorsVol. 26(5)
Plovdiv University (BG), Sofia University "St. Kliment Ohridski" (BG)
European Commission
Openalex Percentile: Top 48%
Radioactivity and Radon Measurements
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.