Peripheral refractive errors in pseudophakic eyes: <i>in vitro</i> evaluation and optical simulation

We present a systematic assessment of peripheral refractive errors in pseudophakic eyes. Optical bench measurements were performed using a physical eye model to characterize the peripheral cylinder of eight different intraocular lens (IOL) models of approximate power 20 D, covering different IOL types (monofocal, enhanced monofocal, extended depth of focus, bifocal, trifocal) and technologies (refractive, diffractive, wavefront-shaping) from several manufacturers. In addition, optical simulations were done for average and personalized pseudophakic eye models. Peripheral cylinder at 20° visual field was similar for all IOLs (range −2.24 to −2.87 D). Simulations in average eye models further showed the peripheral cylinder to be independent of pupil size, retinal radius of curvature (ROC), and IOL technology (−2.31 to −2.62 D across all conditions). Peripheral blur parameter (range 1.24 to 2.03 D across all conditions) showed small variations with IOL technology and ROC but negligible change with different pupil sizes. For simulations with personalized eye models, the peripheral cylinder and blur showed small variation across different IOL technologies.

Authors

Institutions

Publication Details

Journal
Biomedical Optics Express
Published
2026-02-25
DOI
https://doi.org/10.1364/boe.588145
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Peripheral refractive errors in pseudophakic eyes: in vitro evaluation and optical simulation

Dmitry Romashchenko, David A. Atchison, Michael W. Jenkins, Mihai State et al.
Biomedical Optics Express
Ophthalmology and Visual Impairment Studies
article

Peripheral refractive errors in pseudophakic eyes: in vitro evaluation and optical simulation

Dmitry Romashchenko, David A. Atchison, Michael W. Jenkins, Mihai State, Aixa Alarcon, Carmen Canovas
article en

Abstract

We present a systematic assessment of peripheral refractive errors in pseudophakic eyes. Optical bench measurements were performed using a physical eye model to characterize the peripheral cylinder of eight different intraocular lens (IOL) models of approximate power 20 D, covering different IOL types (monofocal, enhanced monofocal, extended depth of focus, bifocal, trifocal) and technologies (refractive, diffractive, wavefront-shaping) from several manufacturers. In addition, optical simulations were done for average and personalized pseudophakic eye models. Peripheral cylinder at 20° visual field was similar for all IOLs (range −2.24 to −2.87 D). Simulations in average eye models further showed the peripheral cylinder to be independent of pupil size, retinal radius of curvature (ROC), and IOL technology (−2.31 to −2.62 D across all conditions). Peripheral blur parameter (range 1.24 to 2.03 D across all conditions) showed small variations with IOL technology and ROC but negligible change with different pupil sizes. For simulations with personalized eye models, the peripheral cylinder and blur showed small variation across different IOL technologies.

Biomedical Optics ExpressVol. 17(4)
Queensland University of Technology (AU), Johnson & Johnson (Sweden) (SE)
Openalex Percentile: Top 44%
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.