Experimental analysis of fire growth and thermal response in clothing retail layouts

This study investigates fire growth and thermal response in clothing retail stores, focusing on hanger arrangement, product density, and fire load. Full-scale burning tests were conducted in a fire room designed for two experimental setups: A1 (single-row hanger, 20 kg of products) and B1 (linear wall unit with circular free-standing hanger, 40 kg). Temperatures, CO, CO 2 , and O 2 concentrations were obtained during tests. Results showed maximum heat release rates of 1991 kW (A1) and 2308 kW (B1), with fire spread to the circular hanger group in B1 at 493 s. CO exceeded critical levels 1.5 min after ignition, O 2 dropped to critical levels at 11 min, and CO 2 surpassed exposure limits at 4 min. The experiments highlight the influence of product arrangement and spacing on fire propagation, gas emissions, and heat release, providing critical data for performance-based fire safety design and evacuation planning in retail textile environments.

Authors

Institutions

Publication Details

Journal
Journal of Fire Sciences
Published
2026-02-25
DOI
https://doi.org/10.1177/07349041261424169
Primary Topic
Fire dynamics and safety research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental analysis of fire growth and thermal response in clothing retail layouts

Fahri Şahin, Cemil Sağlam, Gokhan Coskun
Journal of Fire Sciences
Fire dynamics and safety research
article

Experimental analysis of fire growth and thermal response in clothing retail layouts

Fahri Şahin, Cemil Sağlam, Gokhan Coskun
article en

Abstract

This study investigates fire growth and thermal response in clothing retail stores, focusing on hanger arrangement, product density, and fire load. Full-scale burning tests were conducted in a fire room designed for two experimental setups: A1 (single-row hanger, 20 kg of products) and B1 (linear wall unit with circular free-standing hanger, 40 kg). Temperatures, CO, CO 2 , and O 2 concentrations were obtained during tests. Results showed maximum heat release rates of 1991 kW (A1) and 2308 kW (B1), with fire spread to the circular hanger group in B1 at 493 s. CO exceeded critical levels 1.5 min after ignition, O 2 dropped to critical levels at 11 min, and CO 2 surpassed exposure limits at 4 min. The experiments highlight the influence of product arrangement and spacing on fire propagation, gas emissions, and heat release, providing critical data for performance-based fire safety design and evacuation planning in retail textile environments.

Journal of Fire Sciences
Sakarya University (TR)
Openalex Percentile: Top 56%
Fire dynamics and safety research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.