Depression Detection from Three-Channel Resting-State EEG Using a Hybrid Conv1D and Spectral–Statistical Fusion Model

Major depressive disorder requires scalable, low-burden screening tools. We examined whether three-channel resting-state EEG can support reliable discrimination between major depressive disorder and healthy controls using a lightweight model compatible with portable implementations. This work makes three main contributions: (i) a compact hybrid fusion model combining raw-window Conv1D embeddings with per-channel spectral-statistical descriptors for three-channel resting-state EEG, (ii) a leakage-resistant subject-independent (cross-subject) evaluation protocol with subject-level inference via majority voting, and (iii) a preliminary external feasibility test on an independent portable three-channel cohort without fine-tuning. The proposed model fuses a Conv1D encoding of raw ≈15 s eyes-closed windows (3840 samples; 15.36 s at 250 Hz) with per-channel spectral and statistical descriptors. Training uses subject-independent splits to avoid leakage, class weighting, and data augmentation (including MixUp); hyperparameters are selected via randomized search with refinement. The model is trained on a publicly available MDD dataset and subsequently applied, without fine-tuning, on an independent acquisition of 20 subjects recorded with a portable three-channel device; we report both window-level and subject-level (majority-vote) performance. On the held-out test subjects from the public dataset, the hybrid model attains 93.43% window-level accuracy. The independent evaluation is reported as a preliminary external feasibility analysis; given the small cohort, we report subject-level performance with 95% confidence intervals to reflect uncertainty and avoid over-interpreting cross-device generalization. The model occupies approximately 40.19 MB on disk, and the architecture is compatible with post-training int8 (TFLite) quantization for resource-constrained hardware. These results, obtained on limited samples, support the feasibility of three-channel EEG for major depressive disorder detection using a lightweight hybrid architecture and motivate prospective clinical validation, on-device inference and quantization studies, and broader evaluation across centers and devices.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-02-24
DOI
https://doi.org/10.3390/s26051417
Primary Topic
EEG and Brain-Computer Interfaces
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Depression Detection from Three-Channel Resting-State EEG Using a Hybrid Conv1D and Spectral–Statistical Fusion Model

Florin-Ciprian Argatu, Oana-Isabela Știrbu, Felix-Constantin Adochiei, George-Călin Serițan
Sensors
EEG and Brain-Computer Interfaces
article

Depression Detection from Three-Channel Resting-State EEG Using a Hybrid Conv1D and Spectral–Statistical Fusion Model

Florin-Ciprian Argatu, Oana-Isabela Știrbu, Felix-Constantin Adochiei, George-Călin Serițan
article en

Abstract

Major depressive disorder requires scalable, low-burden screening tools. We examined whether three-channel resting-state EEG can support reliable discrimination between major depressive disorder and healthy controls using a lightweight model compatible with portable implementations. This work makes three main contributions: (i) a compact hybrid fusion model combining raw-window Conv1D embeddings with per-channel spectral-statistical descriptors for three-channel resting-state EEG, (ii) a leakage-resistant subject-independent (cross-subject) evaluation protocol with subject-level inference via majority voting, and (iii) a preliminary external feasibility test on an independent portable three-channel cohort without fine-tuning. The proposed model fuses a Conv1D encoding of raw ≈15 s eyes-closed windows (3840 samples; 15.36 s at 250 Hz) with per-channel spectral and statistical descriptors. Training uses subject-independent splits to avoid leakage, class weighting, and data augmentation (including MixUp); hyperparameters are selected via randomized search with refinement. The model is trained on a publicly available MDD dataset and subsequently applied, without fine-tuning, on an independent acquisition of 20 subjects recorded with a portable three-channel device; we report both window-level and subject-level (majority-vote) performance. On the held-out test subjects from the public dataset, the hybrid model attains 93.43% window-level accuracy. The independent evaluation is reported as a preliminary external feasibility analysis; given the small cohort, we report subject-level performance with 95% confidence intervals to reflect uncertainty and avoid over-interpreting cross-device generalization. The model occupies approximately 40.19 MB on disk, and the architecture is compatible with post-training int8 (TFLite) quantization for resource-constrained hardware. These results, obtained on limited samples, support the feasibility of three-channel EEG for major depressive disorder detection using a lightweight hybrid architecture and motivate prospective clinical validation, on-device inference and quantization studies, and broader evaluation across centers and devices.

SensorsVol. 26(5)
Universitatea Națională de Știință și Tehnologie Politehnica București (RO)
Peace, Justice and strong institutions, Reduced inequalities
Openalex Percentile: Top 47%
EEG and Brain-Computer Interfaces
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.