Flow and droplet evaporation characteristics of high parameter temperature and pressure reducing valves under off-design conditions

The temperature and pressure reducing valve exhibits complex flow, heat, and mass transfer characteristics under off-design conditions. A three-dimensional simulation model of a multi-stage high-temperature and pressure reducing valve (MSHTPRV) was established through the combination of Euler-Lagrange two-phase flow and droplet evaporation models. The temperature and pressure reduction mechanism, as well as the thermal-mass transfer characteristics during droplet evaporation, were investigated. The influence of valve opening on steam flow rate, thermal-mass transfer capabilities, and flow field characteristics was analyzed.The results indicate that the flow rate increases significantly within the 30%–40% opening range and exhibits relatively slow growth in the 60%–100% range. The pressure, temperature, and turbulent kinetic energy inside the valve all decline as the valve opening decreases. When the valve opening is reduced from 100% to 30%, the average pressure inside the valve decreases from 7.65 MPa to 6.88 MPa, and the average temperature drops from 728.29 K to 713.89 K. The mass fraction of newly evaporated steam at the wall above the second-stage throttling orifice plate increases from 0.13 to 0.27, while the turbulent kinetic energy at the right wall of the first-stage throttling orifice plate rises from 4,039 m 2 /s 2 to 31,708 m 2 /s 2 .The vortex motion of steam between the first- and second-stage throttling orifice plates intensifies, enhancing the mixing of steam and droplets and accelerating droplet evaporation, thereby improving the cooling effect. After passing through the third-stage throttling orifice plate, both the eddy viscosity and turbulent kinetic energy decrease, reducing heat and mass transfer capabilities. At a valve opening of 50%, the droplet evaporation rate reaches its maximum at 90.9%, but the energy loss due to steam work increases.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2026-02-25
DOI
https://doi.org/10.1016/j.csite.2026.107855
Primary Topic
Nanomaterials and Printing Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Flow and droplet evaporation characteristics of high parameter temperature and pressure reducing valves under off-design conditions

GUO Kangning, Ren Yuqi, Tong Zhongxiang, Si Heyong et al.
Case Studies in Thermal Engineering
Nanomaterials and Printing Technologies
article

Flow and droplet evaporation characteristics of high parameter temperature and pressure reducing valves under off-design conditions

GUO Kangning, Ren Yuqi, Tong Zhongxiang, Si Heyong, Ju Honghe
article en

Abstract

The temperature and pressure reducing valve exhibits complex flow, heat, and mass transfer characteristics under off-design conditions. A three-dimensional simulation model of a multi-stage high-temperature and pressure reducing valve (MSHTPRV) was established through the combination of Euler-Lagrange two-phase flow and droplet evaporation models. The temperature and pressure reduction mechanism, as well as the thermal-mass transfer characteristics during droplet evaporation, were investigated. The influence of valve opening on steam flow rate, thermal-mass transfer capabilities, and flow field characteristics was analyzed.The results indicate that the flow rate increases significantly within the 30%–40% opening range and exhibits relatively slow growth in the 60%–100% range. The pressure, temperature, and turbulent kinetic energy inside the valve all decline as the valve opening decreases. When the valve opening is reduced from 100% to 30%, the average pressure inside the valve decreases from 7.65 MPa to 6.88 MPa, and the average temperature drops from 728.29 K to 713.89 K. The mass fraction of newly evaporated steam at the wall above the second-stage throttling orifice plate increases from 0.13 to 0.27, while the turbulent kinetic energy at the right wall of the first-stage throttling orifice plate rises from 4,039 m 2 /s 2 to 31,708 m 2 /s 2 .The vortex motion of steam between the first- and second-stage throttling orifice plates intensifies, enhancing the mixing of steam and droplets and accelerating droplet evaporation, thereby improving the cooling effect. After passing through the third-stage throttling orifice plate, both the eddy viscosity and turbulent kinetic energy decrease, reducing heat and mass transfer capabilities. At a valve opening of 50%, the droplet evaporation rate reaches its maximum at 90.9%, but the energy loss due to steam work increases.

Case Studies in Thermal EngineeringVol. 80
Northeast Electric Power University (CN)
Affordable and clean energy
Openalex Percentile: Top 45%
Nanomaterials and Printing Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.