Topology optimization-devised tri-material liquid cooling plate for energy storage battery thermal management

• A tri-material topology optimization is built for battery thermal management. • Multi-physics model unveils dynamic and uneven battery thermal behaviors. • Optimized cooling plate outperforms in cooling efficiency and flow resistance. • Comparative analysis evaluates the bottom versus side cooling designs. Traditional designs of liquid cooling plates using single thermally conductive material are either constrained by predefined topologies or fail to adequately mitigate hotspot issues, which remain insufficient for design freedom and performance trade-offs. To overcome these limitations, we propose a density-based topology optimization model that simultaneously optimizes the layout of flow channels and spatial distribution of two thermally conductive solids—enabling functional structures tailored to poorly ventilated areas. The tri-material liquid cooling plate integrates conjugate heat transfer modeling with a multi-physics battery model to accurately capture the electrochemical-thermal-hydrodynamic interaction in 46.59 kWh battery module. The optimized design yields bifurcated flow patterns that reduce fluid energy dissipation by up to 19.5 and 12.6 %, respectively, compared to straight-channel and single-solid designs at Reynolds number of 900, while improving thermal diffusion performance by over 10 % in terms of performance evaluation criterion. The comparative analysis further reveals that side-mounted composite cold plate outperforms the bottom-mounted counterpart under high discharge rates of 0.5–1C, achieving comprehensive evaluation improvements of 0.09–0.12 due to shorter heat transfer paths and increased thermal contact areas. These results demonstrate that tri-material topology optimization enables co-design of structure and material distribution, offering a scalable solution for high-efficiency and cost-effective liquid cooling design in energy storage systems.

Authors

Institutions

Publication Details

Journal
Energy Conversion and Management
Published
2026-02-25
DOI
https://doi.org/10.1016/j.enconman.2026.121268
Primary Topic
Advanced Battery Technologies Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Topology optimization-devised tri-material liquid cooling plate for energy storage battery thermal management

Xiang-Wei Lin, Xinyi Lin, Liejin Guo, Zhi-Fu Zhou et al.
Energy Conversion and Management
Advanced Battery Technologies Research
article

Topology optimization-devised tri-material liquid cooling plate for energy storage battery thermal management

Xiang-Wei Lin, Xinyi Lin, Liejin Guo, Zhi-Fu Zhou, Zhi-Jun Li, Menglin Yu
article en

Abstract

• A tri-material topology optimization is built for battery thermal management. • Multi-physics model unveils dynamic and uneven battery thermal behaviors. • Optimized cooling plate outperforms in cooling efficiency and flow resistance. • Comparative analysis evaluates the bottom versus side cooling designs. Traditional designs of liquid cooling plates using single thermally conductive material are either constrained by predefined topologies or fail to adequately mitigate hotspot issues, which remain insufficient for design freedom and performance trade-offs. To overcome these limitations, we propose a density-based topology optimization model that simultaneously optimizes the layout of flow channels and spatial distribution of two thermally conductive solids—enabling functional structures tailored to poorly ventilated areas. The tri-material liquid cooling plate integrates conjugate heat transfer modeling with a multi-physics battery model to accurately capture the electrochemical-thermal-hydrodynamic interaction in 46.59 kWh battery module. The optimized design yields bifurcated flow patterns that reduce fluid energy dissipation by up to 19.5 and 12.6 %, respectively, compared to straight-channel and single-solid designs at Reynolds number of 900, while improving thermal diffusion performance by over 10 % in terms of performance evaluation criterion. The comparative analysis further reveals that side-mounted composite cold plate outperforms the bottom-mounted counterpart under high discharge rates of 0.5–1C, achieving comprehensive evaluation improvements of 0.09–0.12 due to shorter heat transfer paths and increased thermal contact areas. These results demonstrate that tri-material topology optimization enables co-design of structure and material distribution, offering a scalable solution for high-efficiency and cost-effective liquid cooling design in energy storage systems.

Energy Conversion and ManagementVol. 354
Xi'an Jiaotong University (CN)
Affordable and clean energy
Openalex Percentile: Top 47%
Advanced Battery Technologies Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.