Optical Coherence Tomography Velocimetry for In-Line Processing of Biologics: Concentrated and Gelling Monoclonal Antibody Solutions

Optical coherence tomography velocimetry (OCTV) was demonstrated with in-line processing of biologics for the first time. OCTV allowed the velocity of concentrated monoclonal antibodies (mAbs at 39.5–84.7 mg mL–1) to be probed in 3.4 pL volumes over distances 0–5 mm from the pipe walls. The large penetration depth is facilitated by the relatively low turbidity of mAbs at near-infrared wavelengths (1300 nm). The mAb solutions could be concentrated in situ and the changes to the viscoelasticity measured. Higher concentration mAb solutions became shear thinning (following the power law fluid model) and the amplitude of their velocity fluctuations decreased. Furthermore, dropping the pH of the mAb solutions induced a gelation phase transition and complex changes to the mAb rheology could be observed with OCTV e.g. thixotropy and the formation of a stationary boundary layer. Thus, in situ formulation of mAbs could be explored with OCTV under industrially relevant conditions.

Authors

Institutions

Publication Details

Journal
ACS Engineering Au
Published
2026-02-24
DOI
https://doi.org/10.1021/acsengineeringau.5c00083
Primary Topic
Optical Coherence Tomography Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optical Coherence Tomography Velocimetry for In-Line Processing of Biologics: Concentrated and Gelling Monoclonal Antibody Solutions

Charles T. Heise, J. C. K. Tovey, Conor M. Lewis, Owen Watts Moore et al.
ACS Engineering Au
Optical Coherence Tomography Applications
article

Optical Coherence Tomography Velocimetry for In-Line Processing of Biologics: Concentrated and Gelling Monoclonal Antibody Solutions

Charles T. Heise, J. C. K. Tovey, Conor M. Lewis, Owen Watts Moore, Thomas Andrew Waigh
article en

Abstract

Optical coherence tomography velocimetry (OCTV) was demonstrated with in-line processing of biologics for the first time. OCTV allowed the velocity of concentrated monoclonal antibodies (mAbs at 39.5–84.7 mg mL–1) to be probed in 3.4 pL volumes over distances 0–5 mm from the pipe walls. The large penetration depth is facilitated by the relatively low turbidity of mAbs at near-infrared wavelengths (1300 nm). The mAb solutions could be concentrated in situ and the changes to the viscoelasticity measured. Higher concentration mAb solutions became shear thinning (following the power law fluid model) and the amplitude of their velocity fluctuations decreased. Furthermore, dropping the pH of the mAb solutions induced a gelation phase transition and complex changes to the mAb rheology could be observed with OCTV e.g. thixotropy and the formation of a stationary boundary layer. Thus, in situ formulation of mAbs could be explored with OCTV under industrially relevant conditions.

ACS Engineering Au
University of Manchester (GB), Fujifilm (United Kingdom) (GB)
Openalex Percentile: Top 46%
Optical Coherence Tomography Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.