Reduced-Switch Active Power Filter with Modified One-Cycle Control for Non-Ideal Voltage Conditions

With the evolution of new power systems, harmonic sources in distribution networks have become increasingly dispersed, thus requiring lower-cost harmonic mitigation devices suitable for large-scale deployment. With its simple control architecture, the one-cycle controlled active power filter (APF) is better adapted to meet the aforementioned requirements. That said, under non-ideal voltage conditions like voltage distortion or unbalance, the compensating target current of the APF that relies on traditional one-cycle control (OCC) will undergo distortion as well, resulting in a substantial reduction in the compensation effect. This paper introduces a modified OCC method based on a positive-sequence filter, which allows for the control of a reduced-switch three-phase APF. This control method eliminates the negative sequence and harmonic components in the target current of the APF, and makes the compensated current maintain a good sinusoidal waveform. A one-cycle control equation applied to the reduced-switch APF was derived. The modified one-cycle control method allows the active filter to retain a favorable compensation effect when operating under non-ideal voltage conditions. Meanwhile, it preserves the inherent advantages of traditional one-cycle control, including the elimination of a phase-locked loop (PLL), a fixed switching frequency, and a straightforward control structure. Finally, an APF simulation model and a dSPACE-based APF experimental circuit were built to verify the proposed control method. In simulation, with the adoption of the modified OCC, the THD of the current was reduced from 8.25% before improvement to 3.79% after improvement. In experiments, according to the spectrum analysis function of the oscilloscope, the third-order current harmonic caused by voltage distortion was decreased from 500 mA to 100 mA, representing a reduction of 80%. Both simulation and experimental results verify that the proposed modified one-cycle control method can effectively solve the problem that control performance is susceptible to voltage quality.

Authors

Institutions

Publication Details

Journal
Processes
Published
2026-02-24
DOI
https://doi.org/10.3390/pr14050733
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reduced-Switch Active Power Filter with Modified One-Cycle Control for Non-Ideal Voltage Conditions

Wenqiang Zhang, Honglan Pei, Lidong Wang, Wenna Zhang et al.
Processes
Power Quality and Harmonics
article

Reduced-Switch Active Power Filter with Modified One-Cycle Control for Non-Ideal Voltage Conditions

Wenqiang Zhang, Honglan Pei, Lidong Wang, Wenna Zhang, Lei Wang
article en

Abstract

With the evolution of new power systems, harmonic sources in distribution networks have become increasingly dispersed, thus requiring lower-cost harmonic mitigation devices suitable for large-scale deployment. With its simple control architecture, the one-cycle controlled active power filter (APF) is better adapted to meet the aforementioned requirements. That said, under non-ideal voltage conditions like voltage distortion or unbalance, the compensating target current of the APF that relies on traditional one-cycle control (OCC) will undergo distortion as well, resulting in a substantial reduction in the compensation effect. This paper introduces a modified OCC method based on a positive-sequence filter, which allows for the control of a reduced-switch three-phase APF. This control method eliminates the negative sequence and harmonic components in the target current of the APF, and makes the compensated current maintain a good sinusoidal waveform. A one-cycle control equation applied to the reduced-switch APF was derived. The modified one-cycle control method allows the active filter to retain a favorable compensation effect when operating under non-ideal voltage conditions. Meanwhile, it preserves the inherent advantages of traditional one-cycle control, including the elimination of a phase-locked loop (PLL), a fixed switching frequency, and a straightforward control structure. Finally, an APF simulation model and a dSPACE-based APF experimental circuit were built to verify the proposed control method. In simulation, with the adoption of the modified OCC, the THD of the current was reduced from 8.25% before improvement to 3.79% after improvement. In experiments, according to the spectrum analysis function of the oscilloscope, the third-order current harmonic caused by voltage distortion was decreased from 500 mA to 100 mA, representing a reduction of 80%. Both simulation and experimental results verify that the proposed modified one-cycle control method can effectively solve the problem that control performance is susceptible to voltage quality.

ProcessesVol. 14(5)
Yuncheng University (CN), Taiyuan Heavy Industry (China) (CN), Shanghai Electric (China) (CN), Taiyuan University of Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 45%
Power Quality and Harmonics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.