Maintaining a 2170 lithium-ion battery’s operating temperature in freezing climates using preheating and an alumina foam PCM structure

This study develops a combined preheating and passive cooling strategy to maintain a 2170 lithium-ion battery (LIB) within its optimal operating temperature range of 15-35 °C under freezing conditions. A computational fluid dynamics (CFD) model based on the finite volume method (FVM) is employed to simulate a thermal management structure composed of high-porosity Al₂O₃ foam (ε = 0.9) impregnated with hexadecane as the phase change material (PCM), coupled with an external preheating technique. This work provides a system-level assessment of preheating duration, energy consumption, PCM utilization, and thermal regulation under extreme cold-start conditions down to - 40 °C, demonstrating stable temperature uniformity, effective latent heat absorption, and improved thermal safety for cold-climate battery applications. The results show that the preheating stage effectively raises the cell temperature to 15 °C, while the PCM-Al₂O₃ foam matrix maintains the temperature below 35 °C during discharge. Across all operating conditions, both the average temperature (T<sub>avg</sub>) and maximum temperature (T<sub>max</sub>) increase with C-rate and environmental temperature. At low C-rates (1-2 C), the available PCM capacity is sufficient to maintain T<sub>avg</sub> = 20 °C and keep T<sub>max</sub> near this level until the end of discharge, whereas at higher C-rates (3-4 C), T<sub>avg</sub> and T<sub>max</sub> rise above 20 °C once the PCM approaches complete melting.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-02-24
DOI
https://doi.org/10.1038/s41598-026-40953-1
Primary Topic
Phase Change Materials Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Maintaining a 2170 lithium-ion battery’s operating temperature in freezing climates using preheating and an alumina foam PCM structure

Omar J. Alkhatib, Shimaa Aly Hussien, Hamdi Ayed, Ali B.M. Ali et al.
Scientific Reports
Phase Change Materials Research
article

Maintaining a 2170 lithium-ion battery’s operating temperature in freezing climates using preheating and an alumina foam PCM structure

Omar J. Alkhatib, Shimaa Aly Hussien, Hamdi Ayed, Ali B.M. Ali, Farzona Tursunzoda, Ibrahim Mahariq, Pradeep Kumar Singh, Mahidzal Dahari
article en

Abstract

This study develops a combined preheating and passive cooling strategy to maintain a 2170 lithium-ion battery (LIB) within its optimal operating temperature range of 15-35 °C under freezing conditions. A computational fluid dynamics (CFD) model based on the finite volume method (FVM) is employed to simulate a thermal management structure composed of high-porosity Al₂O₃ foam (ε = 0.9) impregnated with hexadecane as the phase change material (PCM), coupled with an external preheating technique. This work provides a system-level assessment of preheating duration, energy consumption, PCM utilization, and thermal regulation under extreme cold-start conditions down to - 40 °C, demonstrating stable temperature uniformity, effective latent heat absorption, and improved thermal safety for cold-climate battery applications. The results show that the preheating stage effectively raises the cell temperature to 15 °C, while the PCM-Al₂O₃ foam matrix maintains the temperature below 35 °C during discharge. Across all operating conditions, both the average temperature (T<sub>avg</sub>) and maximum temperature (T<sub>max</sub>) increase with C-rate and environmental temperature. At low C-rates (1-2 C), the available PCM capacity is sufficient to maintain T<sub>avg</sub> = 20 °C and keep T<sub>max</sub> near this level until the end of discharge, whereas at higher C-rates (3-4 C), T<sub>avg</sub> and T<sub>max</sub> rise above 20 °C once the PCM approaches complete melting.

Scientific ReportsVol. 16(1)
Princess Nourah bint Abdulrahman University (SA), Gulf University for Science & Technology (KW), China Medical University (TW), United Arab Emirates University (AE), Al-Quds University (PS), Technological University of Tajikistan (TJ), University of Malaya (MY), Tajik Technical University named after academic M.S.Osimi (TJ), China Medical University Hospital (TW), University of Kerbala (IQ), Korea University (JP), GLA University (IN), King Khalid University (SA), Saveetha University (IN)
Princess Nourah Bint Abdulrahman University, King Khalid University
Climate action
Openalex Percentile: Top 46%
Phase Change Materials Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.