Study on Applicability of Energy-Saving Conductors in Alpine Regions

The development of energy-efficient conductors capable of operating reliably in harsh, cold climates is crucial for sustainable power infrastructure. High-mountain and cold regions are key research scenarios for energy-saving conductors, enabling the natural enhancement of conductor heat dissipation in low-temperature environments and improving the current carrying capacity and energy efficiency. These regions are rich in renewable energy and urgently need efficient transmission channels. However, the extremely complex working conditions create strict requirements for the thermal-mechanical coupling performance of conductors, and existing research has paid insufficient attention to this. This study evaluates the thermal and mechanical performance of three advanced energy-saving conductors (JLHA3-275, JL1/G1A-240/30, JL/LHA1-135/140) in comparison with a conventional conductor (JL/G1A-240/30) under cold-region operating conditions. A finite element analysis model, validated against theoretical calculations under combined meteorological factors, was employed to simulate radial temperature fields and stress distribution. The results demonstrate that the JLHA3 conductor exhibits superior heat dissipation and minimal resistive losses, maintaining a radial temperature of -23.35 °C under a 700 A load, approximately 1.6 °C lower than the conventional type. Its temperature further decreases significantly with increased wind speeds. Thermally, JLHA3 shows high stability across a broad temperature range (-28.85 °C to 29.03 °C). Mechanically, it displays uniform stress distribution and a notable decrease in stress from 79.53 MPa to 39.46 MPa with rising temperatures, indicating excellent flexibility and thermal adaptability. These findings confirm that the JLHA3 conductor offers an optimal combination of thermal performance, structural reliability, and energy efficiency for high-altitude, cold-region power transmission applications.

Authors

Institutions

Publication Details

Journal
Materials
Published
2026-02-24
DOI
https://doi.org/10.3390/ma19050828
Primary Topic
Thermal Analysis in Power Transmission
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on Applicability of Energy-Saving Conductors in Alpine Regions

E Wenqi, H R Liu, Cong Zeng
Materials
Thermal Analysis in Power Transmission
article

Study on Applicability of Energy-Saving Conductors in Alpine Regions

E Wenqi, H R Liu, Cong Zeng
article en

Abstract

The development of energy-efficient conductors capable of operating reliably in harsh, cold climates is crucial for sustainable power infrastructure. High-mountain and cold regions are key research scenarios for energy-saving conductors, enabling the natural enhancement of conductor heat dissipation in low-temperature environments and improving the current carrying capacity and energy efficiency. These regions are rich in renewable energy and urgently need efficient transmission channels. However, the extremely complex working conditions create strict requirements for the thermal-mechanical coupling performance of conductors, and existing research has paid insufficient attention to this. This study evaluates the thermal and mechanical performance of three advanced energy-saving conductors (JLHA3-275, JL1/G1A-240/30, JL/LHA1-135/140) in comparison with a conventional conductor (JL/G1A-240/30) under cold-region operating conditions. A finite element analysis model, validated against theoretical calculations under combined meteorological factors, was employed to simulate radial temperature fields and stress distribution. The results demonstrate that the JLHA3 conductor exhibits superior heat dissipation and minimal resistive losses, maintaining a radial temperature of -23.35 °C under a 700 A load, approximately 1.6 °C lower than the conventional type. Its temperature further decreases significantly with increased wind speeds. Thermally, JLHA3 shows high stability across a broad temperature range (-28.85 °C to 29.03 °C). Mechanically, it displays uniform stress distribution and a notable decrease in stress from 79.53 MPa to 39.46 MPa with rising temperatures, indicating excellent flexibility and thermal adaptability. These findings confirm that the JLHA3 conductor offers an optimal combination of thermal performance, structural reliability, and energy efficiency for high-altitude, cold-region power transmission applications.

MaterialsVol. 19(5)
Northeast Electric Power University (CN), Power Grid Corporation (India) (IN), Huizhou University (CN)
Affordable and clean energy
Openalex Percentile: Top 46%
Thermal Analysis in Power Transmission
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.