Assessment of Radiation Dose in Neurointerventional Procedures Using a Modern Digital Fluoroscopy System

Interventional neuroradiology procedures are among those in which patients and personnel are exposed to the highest radiation dose. This study aims to measure patient doses in terms of dose-area product (DAP) and cumulative air kerma (CAK) for carotid and cerebral angiographic procedures using a digital fluoroscopy system. In addition, the staff dose was measured simultaneously with the patient dose, and the eye lens, finger, and whole-body effective dose was determined per procedure and unit DAP value. The Philips Azurion 7 M20 model C-arm fluoroscopy system was used in this study. At the beginning of the study, quality control and performance evaluations of the system were carried out. DAP and CAK measurement methods were used for patient dose measurement. Staff dose measurement was performed using beryllium oxide (BeO)-based optically stimulated luminescence (OSL) dosimeters positioned at two different points, one dosimeter under the lead apron at waist level and the other at the collar level outside the apron. With these OSL dosimeters, the personnel dose equivalent Hp(10) for the whole body at 10 mm depth, the dose equivalent Hp(3) for the 3-mm-deep eye lens, and the personal dose equivalent Hp(0.07) for the skin at 0.07 mm depth were measured. Patient dose measurements were performed for a total number of 86 patients (65 cerebral and 21 carotid). For cerebral diagnostic/therapeutic procedures, patient mean DAP and CAK values were measured as 73/143 Gy cm2 and 657/1,888 mGy, respectively. Similarly, patient mean DAP and CAK values for carotid diagnostic/therapeutic procedures were measured as 40/79 Gy cm2 and 487/679 mGy, respectively. Patient effective doses calculated from DAP values were 4.04/8.16 mSv and 2.11/3.93 mSv for cerebral diagnostic/therapeutic and carotid diagnostic/therapeutic procedures, respectively. Staff doses were measured for 30 cerebral and 8 carotid examinations simultaneously with patient dose measurements. The calculated whole-body effective doses per examination for the interventional radiologist, nurse, and radiologic technologist were 12.6, 7.1, and 10.0 µSv, respectively. The measured lens doses per procedure for the interventional radiologist, nurse, and radiologic technologist were 18.7, 19.7, and 13.4 µSv, respectively. The extremity doses per procedure were measured as 54.7 µSv for the interventional radiologist, 15.3 µSv for the nurse, and 14.2 µSv for the radiologic technologist.

Authors

Institutions

Publication Details

Journal
Health Physics
Published
2026-02-24
DOI
https://doi.org/10.1097/hp.0000000000002049
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of Radiation Dose in Neurointerventional Procedures Using a Modern Digital Fluoroscopy System

Anıl Arat, Turan Olğar, Tanzer Sancak, S. Ariman et al.
Health Physics
Radiation Dose and Imaging
article

Assessment of Radiation Dose in Neurointerventional Procedures Using a Modern Digital Fluoroscopy System

Anıl Arat, Turan Olğar, Tanzer Sancak, S. Ariman, A. Yalcin
article en

Abstract

Interventional neuroradiology procedures are among those in which patients and personnel are exposed to the highest radiation dose. This study aims to measure patient doses in terms of dose-area product (DAP) and cumulative air kerma (CAK) for carotid and cerebral angiographic procedures using a digital fluoroscopy system. In addition, the staff dose was measured simultaneously with the patient dose, and the eye lens, finger, and whole-body effective dose was determined per procedure and unit DAP value. The Philips Azurion 7 M20 model C-arm fluoroscopy system was used in this study. At the beginning of the study, quality control and performance evaluations of the system were carried out. DAP and CAK measurement methods were used for patient dose measurement. Staff dose measurement was performed using beryllium oxide (BeO)-based optically stimulated luminescence (OSL) dosimeters positioned at two different points, one dosimeter under the lead apron at waist level and the other at the collar level outside the apron. With these OSL dosimeters, the personnel dose equivalent Hp(10) for the whole body at 10 mm depth, the dose equivalent Hp(3) for the 3-mm-deep eye lens, and the personal dose equivalent Hp(0.07) for the skin at 0.07 mm depth were measured. Patient dose measurements were performed for a total number of 86 patients (65 cerebral and 21 carotid). For cerebral diagnostic/therapeutic procedures, patient mean DAP and CAK values were measured as 73/143 Gy cm2 and 657/1,888 mGy, respectively. Similarly, patient mean DAP and CAK values for carotid diagnostic/therapeutic procedures were measured as 40/79 Gy cm2 and 487/679 mGy, respectively. Patient effective doses calculated from DAP values were 4.04/8.16 mSv and 2.11/3.93 mSv for cerebral diagnostic/therapeutic and carotid diagnostic/therapeutic procedures, respectively. Staff doses were measured for 30 cerebral and 8 carotid examinations simultaneously with patient dose measurements. The calculated whole-body effective doses per examination for the interventional radiologist, nurse, and radiologic technologist were 12.6, 7.1, and 10.0 µSv, respectively. The measured lens doses per procedure for the interventional radiologist, nurse, and radiologic technologist were 18.7, 19.7, and 13.4 µSv, respectively. The extremity doses per procedure were measured as 54.7 µSv for the interventional radiologist, 15.3 µSv for the nurse, and 14.2 µSv for the radiologic technologist.

Health Physics
TOBB University of Economics and Technology (TR), Ankara University (TR)
Good health and well-being
Openalex Percentile: Top 45%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.