A seven-year single-center experience with large-bore percutaneous closure in endovascular aneurysm repair

ObjectivesTo evaluate efficacy and safety of percutaneous-endovascular aneurysm repair (p-EVAR) where large-bore access puncture holes were closed with a suture mediated closure device (SMCD) in all eligible patients.MethodsA single-center cohort of prospectively collected data in an Internal Quality Control Registry (IQCR). An "All Comers" cohort of 368 patients with 736 access groins was assessed. All abdominal aortic aneurysm (AAA) patients eligible for p-EVAR after CTA evaluation were included. Patients with stenosis and occlusions requiring vascular Interventions during EVAR were excluded. The groins were stratified into two groups: low-profile (12Fr - 16Fr) and high-profile introducers (18Fr - 20Fr). PerClose ProGlide (Abbott Cardiovascular, IL, USA) and later the newer version PerClose ProStyle (Abbott Cardiovascular, IL, USA) SMCD devices were assessed. Primary endpoints were: <i>Primary ProGlide technical success and Primary assisted percutaneous and non-invasive technical success. Secondary cutdown was an exclusions criterion.</i> Safety endpoints were Freedom from early peri-operative and late 30-day groin access complications requiring vascular surgical intervention.Results<i>Primary technical success</i> was achieved in 66.4 % (473/712) groins<i>. Primary assisted percutaneous and non-invasive technical success</i> was achieved in 32.2 % (229/712) groins. Continuous hemorrhage in 1.4 % (10/712) groins required a cutdown. 98.6 % (712/736) of the groins were successfully closed percutaneously. Median age was 76 years (IQR 71, 80). 78.8 % were male. 92 % (330/368) of the p-EVAR were elective. Median AAA diameter was 57mm (IQR 53, 63). Few groins required surgical intervention. No statically significant differences were found between the PerClose ProGlide and the ProStyle (p < .05).ConclusionsPercutaneous closure is efficient and safe. Low-profile introducers and EVAR components (12Fr - 16Fr) had slightly better primary technical and assisted technical success. 83.5 % of the patient groins were treated with low-profile introducers reflecting the drive in the vascular field toward lower-profile devices. No statistical difference between groups was observed for primary technical success and complication rate.

Authors

Institutions

Publication Details

Journal
Vascular
Published
2026-02-24
DOI
https://doi.org/10.1177/17085381261429288
Primary Topic
Aortic aneurysm repair treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A seven-year single-center experience with large-bore percutaneous closure in endovascular aneurysm repair

Sven R. Mathisen, Simen Tveten Berge
Vascular
Aortic aneurysm repair treatments
article

A seven-year single-center experience with large-bore percutaneous closure in endovascular aneurysm repair

Sven R. Mathisen, Simen Tveten Berge
article en

Abstract

ObjectivesTo evaluate efficacy and safety of percutaneous-endovascular aneurysm repair (p-EVAR) where large-bore access puncture holes were closed with a suture mediated closure device (SMCD) in all eligible patients.MethodsA single-center cohort of prospectively collected data in an Internal Quality Control Registry (IQCR). An "All Comers" cohort of 368 patients with 736 access groins was assessed. All abdominal aortic aneurysm (AAA) patients eligible for p-EVAR after CTA evaluation were included. Patients with stenosis and occlusions requiring vascular Interventions during EVAR were excluded. The groins were stratified into two groups: low-profile (12Fr - 16Fr) and high-profile introducers (18Fr - 20Fr). PerClose ProGlide (Abbott Cardiovascular, IL, USA) and later the newer version PerClose ProStyle (Abbott Cardiovascular, IL, USA) SMCD devices were assessed. Primary endpoints were: <i>Primary ProGlide technical success and Primary assisted percutaneous and non-invasive technical success. Secondary cutdown was an exclusions criterion.</i> Safety endpoints were Freedom from early peri-operative and late 30-day groin access complications requiring vascular surgical intervention.Results<i>Primary technical success</i> was achieved in 66.4 % (473/712) groins<i>. Primary assisted percutaneous and non-invasive technical success</i> was achieved in 32.2 % (229/712) groins. Continuous hemorrhage in 1.4 % (10/712) groins required a cutdown. 98.6 % (712/736) of the groins were successfully closed percutaneously. Median age was 76 years (IQR 71, 80). 78.8 % were male. 92 % (330/368) of the p-EVAR were elective. Median AAA diameter was 57mm (IQR 53, 63). Few groins required surgical intervention. No statically significant differences were found between the PerClose ProGlide and the ProStyle (p < .05).ConclusionsPercutaneous closure is efficient and safe. Low-profile introducers and EVAR components (12Fr - 16Fr) had slightly better primary technical and assisted technical success. 83.5 % of the patient groins were treated with low-profile introducers reflecting the drive in the vascular field toward lower-profile devices. No statistical difference between groups was observed for primary technical success and complication rate.

Vascular
University of Oslo (NO), Innlandet Hospital Trust (NO), Häme University of Applied Sciences (FI)
Reduced inequalities
Openalex Percentile: Top 44%
Aortic aneurysm repair treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.