Impedimetric Detection of Free Fatty Acids in Patient Serum Using Commercially Available Screen-Printed Carbon Electrode

Objective: The performance of chrono-impedance measurement, a novel electrochemical method for determining free fatty acids (FA), was evaluated in a real-world clinical setting. Methods: Patients presenting to the emergency department with chest pain or discomfort were included. Routine diagnostic tests were performed in accredited laboratories. Chrono-impedance was measured using a screen-printed carbon electrode connected to a dedicated potentiostat. Serum total free-FA levels were determined by gas chromatography with flame ionization detection. Results: Among 104 patients, 21 received a specific diagnosis, while the remaining 83 patients were discharged with non-specific pain. Mean free-FA level was 0.9 ± 0.6 mM. Palmitic, linoleic, stearic, oleic, and arachidonic acids accounted for 74.9% of total free FAs. Impedance plots showed a characteristic logarithmic increase over time for all patients. When instantaneous impedance values at four different time points (10, 100, 376.6, and 500 s) were examined, a significantly strong correlation was observed between impedance and FA molarity (r = 0.8312, 0.9897, 0.9947, and 0.9951) and FA weight (r = 0.9572, 0.9878, 0.9996, and 0.9998), respectively. Conclusions: Chrono-impedance demonstrated a very high correlation with total free-FA levels in real patient samples.

Authors

Institutions

Publication Details

Journal
Chemosensors
Published
2026-02-24
DOI
https://doi.org/10.3390/chemosensors14030053
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impedimetric Detection of Free Fatty Acids in Patient Serum Using Commercially Available Screen-Printed Carbon Electrode

Yusuf Ali Altuncı, Evrim Şimşek, Ali Murat Ergin, Hilmiye Deniz Ertuğrul Uygun et al.
Chemosensors
Non-Invasive Vital Sign Monitoring
article

Impedimetric Detection of Free Fatty Acids in Patient Serum Using Commercially Available Screen-Printed Carbon Electrode

Yusuf Ali Altuncı, Evrim Şimşek, Ali Murat Ergin, Hilmiye Deniz Ertuğrul Uygun, İsmail ORAN, Hakan Gökalp Uzun, Şadiye Mıdık, Barış Kılıçaslan, Halil İbrahim Özdemir
article en

Abstract

Objective: The performance of chrono-impedance measurement, a novel electrochemical method for determining free fatty acids (FA), was evaluated in a real-world clinical setting. Methods: Patients presenting to the emergency department with chest pain or discomfort were included. Routine diagnostic tests were performed in accredited laboratories. Chrono-impedance was measured using a screen-printed carbon electrode connected to a dedicated potentiostat. Serum total free-FA levels were determined by gas chromatography with flame ionization detection. Results: Among 104 patients, 21 received a specific diagnosis, while the remaining 83 patients were discharged with non-specific pain. Mean free-FA level was 0.9 ± 0.6 mM. Palmitic, linoleic, stearic, oleic, and arachidonic acids accounted for 74.9% of total free FAs. Impedance plots showed a characteristic logarithmic increase over time for all patients. When instantaneous impedance values at four different time points (10, 100, 376.6, and 500 s) were examined, a significantly strong correlation was observed between impedance and FA molarity (r = 0.8312, 0.9897, 0.9947, and 0.9951) and FA weight (r = 0.9572, 0.9878, 0.9996, and 0.9998), respectively. Conclusions: Chrono-impedance demonstrated a very high correlation with total free-FA levels in real patient samples.

ChemosensorsVol. 14(3)
Izmir University (TR), Dokuz Eylül University (TR), Ege University (TR)
Openalex Percentile: Top 46%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.