Understanding <i>m</i> / <i>z</i> Range Settings for MS/MS Scans: A Case Study with Intact Glycopeptides
Effective glycopeptide identification with tandem mass spectrometry (MS/MS) often relies on both low mass-to-charge (<i>m</i>/<i>z</i>) ions derived from glycan-specific oxonium ions and higher <i>m</i>/<i>z</i> peptide fragment ions that retain glycan modifications. Thus, glycoproteomic experiments benefit from a wider MS/MS scan range, i.e., the breadth of <i>m</i>/<i>z</i> values measured in fragmentation spectra, than those typically used in nonmodified peptide analyses. Here, we explore the implications of breaking a common axiom for scan range settings called the "5-10-15 rule" used to maximize transmission of ion populations of interest. This 5-10-15 rule, which defines the upper <i>m</i>/<i>z</i> value for a scan as a multiple of the first <i>m</i>/<i>z</i> value, comes from fundamental requirements for stable ion trajectories, where voltage settings must balance retention of low <i>m</i>/<i>z</i> ions while also generating effective pseudopotential wells to trap high <i>m</i>/<i>z</i> ions. Adhering to this calculation for MS/MS scan range settings can reduce glycopeptide ion coverage by excluding the analysis of either low <i>m</i>/<i>z</i> oxonium ions or high <i>m</i>/<i>z</i> fragment ions. We use a quadrupole-Orbitrap-linear ion trap Tribrid MS system (Orbitrap Ascend) to investigate the implications of following or breaking the 5-10-15 rule in MS/MS scans for glycopeptide characterization with higher-energy collisional dissociation (HCD), electron-transfer dissociation (ETD), and electron-transfer/higher-energy collision dissociation (EThcD). For scans with a first <i>m</i>/<i>z</i> value around <i>m</i>/<i>z</i> 120 (i.e., capturing most common glycan-specific oxonium ions), we show that breaking the 5-10-15 rule does not lead to a significant loss of fragment ion transmission at either extreme of the <i>m</i>/<i>z</i> range. We use this case study to discuss the concepts important to using the 5-10-15 rule wisely and when it can be practically ignored, such as using large scan ranges to improve glycopeptide characterization.
Authors
- Nicholas M. Riley (ORCID: https://orcid.org/0000-0002-1536-2966)
- Tim S. Veth (ORCID: https://orcid.org/0000-0002-2561-5437)
- Kathryn Kothlow (ORCID: https://orcid.org/0009-0007-3252-0616)
Institutions
- University of Washington (US)
Publication Details
- Journal
- Journal of the American Society for Mass Spectrometry
- Published
- 2026-02-23
- DOI
- https://doi.org/10.1021/jasms.5c00352
- Primary Topic
- Mass Spectrometry Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00