Exploring the effects of short-term indoor CO <sub>2</sub> exposure on heart rate and cognition in university students: A pilot study

Indoor carbon dioxide (CO 2 ) accumulation in university classrooms is associated with fluctuations in students’ cognitive performance. This study investigated the preliminary associations between short-term CO 2 exposure, heart rate (HR), and cognitive accuracy (ACC), leveraging a small-N intensive longitudinal design with 54 synchronized observation sets over 6 days. Results indicated that HR responded to CO 2 in two stages under the observed conditions: an initial sensitive response with relatively stable HR when CO 2 was below the 1000 ppm reference level, followed by a gradual adaptive decline as concentrations increased. Standardized mediation analysis confirmed a global indirect effect (β = −0.106, p &lt; 0.05). Notably, segmented analysis revealed that this physiological-cognitive coupling was primarily driven by the intensified impact of HR on cognitive accuracy in Phase II (β = 0.389, p = 0.022), whereas the mechanism remained exploratory in Phase I. These preliminary findings suggest that the relationship between CO 2 and cognition may be mediated by autonomic regulation (reflected by HR). Under the observed classroom conditions, 1000 ppm may serve as a guideline-aligned environmental reference associated with physiological–cognitive shifts. Practical applications This pilot study suggests that heart rate (HR) mediates the association between indoor CO 2 and cognitive performance in university classrooms. Specifically, CO 2 levels exceeding 1000 ppm were associated with distinct physiological changes and reduced cognitive accuracy, highlighting this value as a critical reference for ventilation control. Practically, these results support implementing occupancy-sensitive ventilation strategies to limit CO 2 accumulation. Additionally, the observed CO 2 -HR coupling indicates that aggregate HR trends derived from wearable devices could serve as non-invasive, supplementary indicators of indoor environmental conditions. These exploratory findings inform future human-centric approaches to indoor environmental quality (IEQ) management in educational settings.

Authors

Institutions

Publication Details

Journal
Building Services Engineering Research and Technology
Published
2026-02-24
DOI
https://doi.org/10.1177/01436244261429218
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Exploring the effects of short-term indoor CO 2 exposure on heart rate and cognition in university students: A pilot study

Dong Jiang, Xiangfei Wei, Xiaoqiang Gong, Zhanzhan Jiao
Building Services Engineering Research and Technology
Indoor Air Quality and Microbial Exposure
article

Exploring the effects of short-term indoor CO 2 exposure on heart rate and cognition in university students: A pilot study

Dong Jiang, Xiangfei Wei, Xiaoqiang Gong, Zhanzhan Jiao
article en

Abstract

Indoor carbon dioxide (CO 2 ) accumulation in university classrooms is associated with fluctuations in students’ cognitive performance. This study investigated the preliminary associations between short-term CO 2 exposure, heart rate (HR), and cognitive accuracy (ACC), leveraging a small-N intensive longitudinal design with 54 synchronized observation sets over 6 days. Results indicated that HR responded to CO 2 in two stages under the observed conditions: an initial sensitive response with relatively stable HR when CO 2 was below the 1000 ppm reference level, followed by a gradual adaptive decline as concentrations increased. Standardized mediation analysis confirmed a global indirect effect (β = −0.106, p &lt; 0.05). Notably, segmented analysis revealed that this physiological-cognitive coupling was primarily driven by the intensified impact of HR on cognitive accuracy in Phase II (β = 0.389, p = 0.022), whereas the mechanism remained exploratory in Phase I. These preliminary findings suggest that the relationship between CO 2 and cognition may be mediated by autonomic regulation (reflected by HR). Under the observed classroom conditions, 1000 ppm may serve as a guideline-aligned environmental reference associated with physiological–cognitive shifts. Practical applications This pilot study suggests that heart rate (HR) mediates the association between indoor CO 2 and cognitive performance in university classrooms. Specifically, CO 2 levels exceeding 1000 ppm were associated with distinct physiological changes and reduced cognitive accuracy, highlighting this value as a critical reference for ventilation control. Practically, these results support implementing occupancy-sensitive ventilation strategies to limit CO 2 accumulation. Additionally, the observed CO 2 -HR coupling indicates that aggregate HR trends derived from wearable devices could serve as non-invasive, supplementary indicators of indoor environmental conditions. These exploratory findings inform future human-centric approaches to indoor environmental quality (IEQ) management in educational settings.

Building Services Engineering Research and Technology
Macau University of Science and Technology (MO), Bozhou People's Hospital (CN)
Quality Education
Openalex Percentile: Top 49%
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.