High-Flow-Rate Trace Formaldehyde Detection Based on Ultraviolet Photoacoustic Spectroscopy Using a Long Resonant Photoacoustic Cell

Formaldehyde (H<sub>2</sub>CO) is a hazardous volatile organic compound widely present in indoor and industrial environments, and its real-time, highly sensitive detection is essential for environmental safety. However, existing detection techniques often face challenges in simultaneously achieving high sensitivity and long-term stability, and many conventional photoacoustic spectroscopy (PAS) systems rely strongly on low gas flow rates to suppress flow-induced noise, which limits their applicability for continuous online monitoring. In this work, an ultraviolet photoacoustic spectroscopy (UV-PAS)-based H<sub>2</sub>CO detection system operating in a nitrogen (N<sub>2</sub>) background is developed. The system integrates a compact differential photoacoustic cell (PAC) with a 320 nm ultraviolet laser source, in which the resonator length and buffer configuration are carefully optimized to enhance acoustic resonance and effectively suppress flow-related disturbances. Notably, a key innovation of this study is that the system maintains a stable photoacoustic response even under relatively high gas flow conditions. Experimental results demonstrate that at a flow rate of 250 sccm, the photoacoustic signal amplitude remains stable, and the noise level is well controlled, significantly reducing the dependence of conventional PAS systems on low-flow operation. The photoacoustic cell exhibits a resonant frequency of 1767 Hz and a quality factor of 46. Calibration using a 47.31 ppm H<sub>2</sub>CO:N<sub>2</sub> gas mixture shows a good linear response with a correlation coefficient of R<sup>2</sup> = 0.98844. The minimum detection limit reaches 2.50 ppm at a 1 s integration time and is further improved to 88.1 ppb at an integration time of 2202 s based on Allan-Werle deviation analysis. These results demonstrate that the proposed UV-PAS system provides a sensitive, stable, and cost-effective solution for real-time trace H<sub>2</sub>CO detection while retaining robust performance at elevated gas flow rates, highlighting its strong potential for practical applications.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-02-24
DOI
https://doi.org/10.3390/s26051410
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-Flow-Rate Trace Formaldehyde Detection Based on Ultraviolet Photoacoustic Spectroscopy Using a Long Resonant Photoacoustic Cell

Deng Zhang, Shibang Ma, Qianjin Gan, Xiu Yang et al.
Sensors
Spectroscopy and Laser Applications
article

High-Flow-Rate Trace Formaldehyde Detection Based on Ultraviolet Photoacoustic Spectroscopy Using a Long Resonant Photoacoustic Cell

Deng Zhang, Shibang Ma, Qianjin Gan, Xiu Yang, Xukun Yin, Zhongqi Feng
article en

Abstract

Formaldehyde (H<sub>2</sub>CO) is a hazardous volatile organic compound widely present in indoor and industrial environments, and its real-time, highly sensitive detection is essential for environmental safety. However, existing detection techniques often face challenges in simultaneously achieving high sensitivity and long-term stability, and many conventional photoacoustic spectroscopy (PAS) systems rely strongly on low gas flow rates to suppress flow-induced noise, which limits their applicability for continuous online monitoring. In this work, an ultraviolet photoacoustic spectroscopy (UV-PAS)-based H<sub>2</sub>CO detection system operating in a nitrogen (N<sub>2</sub>) background is developed. The system integrates a compact differential photoacoustic cell (PAC) with a 320 nm ultraviolet laser source, in which the resonator length and buffer configuration are carefully optimized to enhance acoustic resonance and effectively suppress flow-related disturbances. Notably, a key innovation of this study is that the system maintains a stable photoacoustic response even under relatively high gas flow conditions. Experimental results demonstrate that at a flow rate of 250 sccm, the photoacoustic signal amplitude remains stable, and the noise level is well controlled, significantly reducing the dependence of conventional PAS systems on low-flow operation. The photoacoustic cell exhibits a resonant frequency of 1767 Hz and a quality factor of 46. Calibration using a 47.31 ppm H<sub>2</sub>CO:N<sub>2</sub> gas mixture shows a good linear response with a correlation coefficient of R<sup>2</sup> = 0.98844. The minimum detection limit reaches 2.50 ppm at a 1 s integration time and is further improved to 88.1 ppb at an integration time of 2202 s based on Allan-Werle deviation analysis. These results demonstrate that the proposed UV-PAS system provides a sensitive, stable, and cost-effective solution for real-time trace H<sub>2</sub>CO detection while retaining robust performance at elevated gas flow rates, highlighting its strong potential for practical applications.

SensorsVol. 26(5)
Xidian University (CN)
Openalex Percentile: Top 46%
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.