Fast-Pulsed Nitrogen Discharge for Enhanced Activation and Long-Term Stabilization of Plasma-Generated RONS in Water and Hyaluronic Acid Gel

Plasma-activated medium (PAM) is produced by exposing a liquid solution, consisting of hyaluronic acid gel and deionized water, to nitrogen plasma. Plasma exposure through fast pulsed discharge (FPD) generates reactive oxygen species (ROS) and reactive nitrogen species (RNS) in the liquid. The goal of this work is to figure out how many of these reactive species are in PAM. To test the levels of hydrogen peroxide, nitrite, and nitrate right after treatment and after 96 h of storage, a DC high voltage of about 15 kV was used for 5, 10, 15, and 20 min. The discharge promotes the formation of reactive nitrogen species, leading to moderate RONS levels. These species decay rapidly in water, but the gel remains much more stable due to limited diffusion and a stabilized matrix. Results indicate that fast-pulsed nitrogen discharge is effective and that hyaluronic acid gel efficiently retains plasma-generated reactive species over an extended period.

Authors

Institutions

Publication Details

Journal
Doklady Physical Chemistry
Published
2025-10-01
DOI
https://doi.org/10.1134/s0012501625600858
Primary Topic
Plasma Applications and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fast-Pulsed Nitrogen Discharge for Enhanced Activation and Long-Term Stabilization of Plasma-Generated RONS in Water and Hyaluronic Acid Gel

H. Ahmet Yıldırım, Saif B. Mohammed
Doklady Physical Chemistry
Plasma Applications and Diagnostics
article

Fast-Pulsed Nitrogen Discharge for Enhanced Activation and Long-Term Stabilization of Plasma-Generated RONS in Water and Hyaluronic Acid Gel

H. Ahmet Yıldırım, Saif B. Mohammed
article en

Abstract

Plasma-activated medium (PAM) is produced by exposing a liquid solution, consisting of hyaluronic acid gel and deionized water, to nitrogen plasma. Plasma exposure through fast pulsed discharge (FPD) generates reactive oxygen species (ROS) and reactive nitrogen species (RNS) in the liquid. The goal of this work is to figure out how many of these reactive species are in PAM. To test the levels of hydrogen peroxide, nitrite, and nitrate right after treatment and after 96 h of storage, a DC high voltage of about 15 kV was used for 5, 10, 15, and 20 min. The discharge promotes the formation of reactive nitrogen species, leading to moderate RONS levels. These species decay rapidly in water, but the gel remains much more stable due to limited diffusion and a stabilized matrix. Results indicate that fast-pulsed nitrogen discharge is effective and that hyaluronic acid gel efficiently retains plasma-generated reactive species over an extended period.

Doklady Physical ChemistryVol. 520(5)
Sakarya University (TR), University of Anbar (IQ)
Clean water and sanitation
Openalex Percentile: Top 26%
Plasma Applications and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.