Mechanical and Electrochemical Corrosion Behavior of Porous Ti-10Zr-xNb Alloys Processed via Powder Metallurgy for Biomedical Implants

Titanium alloys are widely used for biomedical implants due to their favorable mechanical properties, corrosion resistance, and biocompatibility; however, their high stiffness relative to bone can lead to stress shielding. This study developed porous Ti-10Zr-xNb alloys (x = 5, 10, 15, 20 wt %) via powder metallurgy using 600 MPa cold compaction, followed by high-vacuum sealed sintering to reduce stiffness through controlled porosity. All alloys exhibited a biphasic α + β microstructure, with the β phase fraction increasing with the Nb content. The Ti-10Zr-20Nb alloy achieved the highest mechanical performance, with a compressive strength of 844.70 ± 20.92 MPa and an elastic modulus of 32.51 ± 1.52 GPa, within the modulus range of cortical bone. Electrochemical tests (OCP, EIS, PDP) conducted in simulated body fluid revealed a gradual decline in corrosion resistance with the increasing Nb content despite nearly constant porosity levels. This behavior is attributed to Nb-induced β phase stabilization and its likely influence on passive film defect chemistry, which may promote defect-assisted charge transport and reduce the barrier effectiveness of the passive film under porous conditions. Among the compositions, Ti-10Zr-5Nb exhibited the highest corrosion resistance, with <i>E</i><sub>corr</sub> = -0.0361 V and <i>I</i><sub>corr</sub> = 17.24 μA/cm<sup>2</sup>, whereas alloys with a higher Nb content showed more negative corrosion potentials and elevated corrosion currents. Overall, Ti-10Zr-20Nb offers the best mechanical compatibility for orthopedic load-bearing implants, whereas Ti-10Zr-5Nb provides favorable electrochemical stability for dental environments.

Authors

Institutions

Publication Details

Journal
ACS Biomaterials Science & Engineering
Published
2026-02-24
DOI
https://doi.org/10.1021/acsbiomaterials.5c01510
Primary Topic
Titanium Alloys Microstructure and Properties
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mechanical and Electrochemical Corrosion Behavior of Porous Ti-10Zr-xNb Alloys Processed via Powder Metallurgy for Biomedical Implants

Dileep Pathote, Amit Raj, Rupesh Kumar, R. K. Gautam
ACS Biomaterials Science & Engineering
Titanium Alloys Microstructure and Properties
article

Mechanical and Electrochemical Corrosion Behavior of Porous Ti-10Zr-xNb Alloys Processed via Powder Metallurgy for Biomedical Implants

Dileep Pathote, Amit Raj, Rupesh Kumar, R. K. Gautam
article en

Abstract

Titanium alloys are widely used for biomedical implants due to their favorable mechanical properties, corrosion resistance, and biocompatibility; however, their high stiffness relative to bone can lead to stress shielding. This study developed porous Ti-10Zr-xNb alloys (x = 5, 10, 15, 20 wt %) via powder metallurgy using 600 MPa cold compaction, followed by high-vacuum sealed sintering to reduce stiffness through controlled porosity. All alloys exhibited a biphasic α + β microstructure, with the β phase fraction increasing with the Nb content. The Ti-10Zr-20Nb alloy achieved the highest mechanical performance, with a compressive strength of 844.70 ± 20.92 MPa and an elastic modulus of 32.51 ± 1.52 GPa, within the modulus range of cortical bone. Electrochemical tests (OCP, EIS, PDP) conducted in simulated body fluid revealed a gradual decline in corrosion resistance with the increasing Nb content despite nearly constant porosity levels. This behavior is attributed to Nb-induced β phase stabilization and its likely influence on passive film defect chemistry, which may promote defect-assisted charge transport and reduce the barrier effectiveness of the passive film under porous conditions. Among the compositions, Ti-10Zr-5Nb exhibited the highest corrosion resistance, with <i>E</i><sub>corr</sub> = -0.0361 V and <i>I</i><sub>corr</sub> = 17.24 μA/cm<sup>2</sup>, whereas alloys with a higher Nb content showed more negative corrosion potentials and elevated corrosion currents. Overall, Ti-10Zr-20Nb offers the best mechanical compatibility for orthopedic load-bearing implants, whereas Ti-10Zr-5Nb provides favorable electrochemical stability for dental environments.

ACS Biomaterials Science & EngineeringVol. 12(3)
Dr. D. Y. Patil Medical College, Hospital and Research Centre (IN), Indian Institute of Technology BHU (IN), Indian Institute of Science Bangalore (IN)
Openalex Percentile: Top 46%
Titanium Alloys Microstructure and Properties
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.