Preparation of Incurred Samples Containing Egg-derived Protein and the Pilot Study for Proficiency Test

In allergen testing of food products, external quality assessment (EQA) programs are essential to ensure high-precision detection and the reliability of results across testing laboratories. However, conventional spiked samples may not sufficiently reflect the nature of processed foods. Therefore, this study examined the applicability of EQA programs using actual food samples that reflect real-world conditions. Twenty-four commercially available food samples were screened using the ELISA method. A coleslaw dressing (CoD) containing 33.1 μg/g of egg-derived protein which is closest to the labeling reference value of 10 μg/g, was selected. The CoD was diluted with egg-free CoD, resulting in a mean concentration of 10.4±0.6 μg/g (RSD 5.3%).Based on this result, approximately 2 kg of an incurred sample (Sample 1) was prepared for a sample in the pilot study for the EQA program, targeting a concentration of 10 μg/g, and its homogeneity and stability were confirmed. A conventional spiked sample (Sample 2) was also prepared with equivalent quality. A pilot study for the EQA program was conducted with 22 institutions. By using two kinds of ELISA kits, the average concentration was 11.9 μg and 9.7 μg for Sample 1 and 8.6 μg/g and 9.3 μg/g for Sample 2. The performance evaluation using robust statistical methods indicated that nearly all measurement results from the institutions fell within the control limits, suggesting that the incurred sample is beneficial as a test material for the EQA program. These results suggest that EQA programs using incurred samples can contribute to improving the reliability of egg allergen testing in food safety management.

Authors

Institutions

Publication Details

Journal
Food Hygiene and Safety Science (Shokuhin Eiseigaku Zasshi)
Published
2026-02-24
DOI
https://doi.org/10.3358/shokueishi.67.16
Primary Topic
Animal Genetics and Reproduction
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Preparation of Incurred Samples Containing Egg-derived Protein and the Pilot Study for Proficiency Test

Shinobu Wakuri, Y. Iwasaki, Takaho Watanabe, Mai Hosoya et al.
Food Hygiene and Safety Science (Shokuhin Eiseigaku Zasshi)
Animal Genetics and Reproduction
article

Preparation of Incurred Samples Containing Egg-derived Protein and the Pilot Study for Proficiency Test

Shinobu Wakuri, Y. Iwasaki, Takaho Watanabe, Mai Hosoya, Rie Ito, Hiroshi Akiyama, Kana Uchida, Shihomi Kuwano
article en

Abstract

In allergen testing of food products, external quality assessment (EQA) programs are essential to ensure high-precision detection and the reliability of results across testing laboratories. However, conventional spiked samples may not sufficiently reflect the nature of processed foods. Therefore, this study examined the applicability of EQA programs using actual food samples that reflect real-world conditions. Twenty-four commercially available food samples were screened using the ELISA method. A coleslaw dressing (CoD) containing 33.1 μg/g of egg-derived protein which is closest to the labeling reference value of 10 μg/g, was selected. The CoD was diluted with egg-free CoD, resulting in a mean concentration of 10.4±0.6 μg/g (RSD 5.3%).Based on this result, approximately 2 kg of an incurred sample (Sample 1) was prepared for a sample in the pilot study for the EQA program, targeting a concentration of 10 μg/g, and its homogeneity and stability were confirmed. A conventional spiked sample (Sample 2) was also prepared with equivalent quality. A pilot study for the EQA program was conducted with 22 institutions. By using two kinds of ELISA kits, the average concentration was 11.9 μg and 9.7 μg for Sample 1 and 8.6 μg/g and 9.3 μg/g for Sample 2. The performance evaluation using robust statistical methods indicated that nearly all measurement results from the institutions fell within the control limits, suggesting that the incurred sample is beneficial as a test material for the EQA program. These results suggest that EQA programs using incurred samples can contribute to improving the reliability of egg allergen testing in food safety management.

Food Hygiene and Safety Science (Shokuhin Eiseigaku Zasshi)Vol. 67(1)
Hoshi University (JP), Food and Drug Safety Center (JP)
Openalex Percentile: Top 43%
Animal Genetics and Reproduction
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.